TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-L
FEIG ELECTRONIC GmbH
Page 62 of 71
FUZ2-A-B-C-CX-L_Montageanleitung_GB
_10.docx
No.
Description
I.621
The resolution of the installed position encoder is too low to maintain robust light curtain operation.
More increments are required per door move. (Message only occurs when DIP-Switch is ON.)
I.700
In timer limit switch operating mode (typ. after power on) the door position is not available. Deadman speed is maintained until the actual position
becomes available again.
I.856
The internal safety edge is tripped because of an WiCab radio problem
The radio connection interrupts during door drive for a short time. Possible causes are:
• The Distance between mobile and stationary unit is larger than specified
• No perfect Orientation of stationary and mobile antenna
• The radio link is disturbed by external noise