5.5.2
Electrical resistance safety edge
8
K
2
Outside
white
Inside
brown
66
65
64
63
62
61
brown
white
Jumper J 801 is located to
the left and behind
terminal 51 - 52
J801 = 1-2
8,2K
1,2K
4
digital
Parameter P.5A2 = 3
3
2
1
Figure 14: Connecting an electrical resistance - safety edge
5.5.3
Digital input
66
65
64
63
62
61
Jumper J 801 is located to
the left and behind
terminal 51 - 52
J801 = 3-4
8,2K
1,2K
4
digital
Parameter P.5A2 = 0
3
2
1