TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-L
FEIG ELECTRONIC GmbH
Page 46 of 71
FUZ2-A-B-C-CX-L_Montageanleitung_GB
_10.docx
The subsequent OPENING and CLOSING of the door in
automatic mode adjusts the pre-limit switches and limit switch
tapes are taught-in automatically.
2.
Start correction drive by pressing the
OPEN-key.
! Korrekturfahrt !
xxx Start mit
I.515
Door opens and is taught-in into the position.
Door opens.
I.555 Lern Fahrt
I.555
Display in end position OPEN.
Offenh= xxs
I.515 Korr. Fahrt
I.515
The door will close automatically after the auto close time has
count down and moves up and down by itself until the correction
drive has finished.
The Display shows the following messages:
Door closes.
I.515 Korr. Fahrt
I.515
Offenhalt = xxs
I515 Korrekt. Fahrt
I.515
Display that correction was completed.
Optional display during a subsequent correction.
The door closes and remains in the end position CLOSE.
Offenh 1 = xxs
I.510 Korrek. OK
T.5
Offenh 1 = xxs
Automatik
T.5
Door opens.
I.515
`AUF`
Offenh 1 = xxs
I 100 Auf Geschw.
I.100
Offenh 1 = xxs
T10
Door closes.
2
UF`
The commissioning of the light curtain has been successfully
completed.
FEIG ELECTRONIC
xxx Zyklen
_EU_
The end position CLOSE must usually be corrected subsequently. This can be performed via the
following parameters:
221: Correction value end position door CLOSE -> this parameter must be reset after every new teach-in of
all end positions (P.210=5).
P.275: Correction of increments after conclusion of the synchronization -> recommended as fine setting for
the end position BELOW. The value set here must NOT be re-set after the new teach-in of all end positions.