TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-L
FEIG ELECTRONIC GmbH
Page 31 of 71
FUZ2-A-B-C-CX-L_Montageanleitung_GB
_10.docx
5.12 Overview of inputs
86 - +24 V
85 - Input 7:
Manual / automatic
84 - GND
83 - +24 V
82 - Input 6:
Permanent OPEN
81 - GND
76 - +24 V
75 - Input 5:
photo eye
74 - GND
73 - +24 V
72 - Input 4:
Pull switch (Open & Close)
71 - GND
66 - Output 15:
+24 V
65 - Input 10:
Disable auto close time
64 - Input 9:
Cross traffic
63 - GND
62 - +24 V
61 - Input 8:
Locking endposition CLOSE
54 - Input 3:
CLOSE
53 - Input 2:
STOP
52 - Input 1:
OPEN
51 - +24 V
45 - +12 V
44 - GND
43 - Safety edge
Safety edge closing
42 - E-stop 1
41 - E-stop 1
36* - GND
35* - Channel B
34* - Channel A
33* - +12 V
32* - E-stop 2
31* - E-stop 2
8K2
10
9
8
7
6
#
5
#
3 / blue
2 / white
4 / black
1 / brown
3
2
4
6
5
1
#
Only with TST PE_FSBS
Figure 26: Overview of inputs
On the control option
–B, input 10 is used as a second safety edge monitor.
For the connection of mech. limit switches, please refer to section5.7.4 Mechanical limit switches.