14 Specifications
Housing dimensions (W x H x D)
Version -A / -B
182 x 328 x 102 mm (with spacers)
Version -C / -CX
182 x 328 x 121 mm
Version -CGH / -CXGH / -LGH
210 x 420 x 200 mm
Assembly:
Vertical using wall bracket on housing bottom
Supply voltage over
L, N, PE
230 V
AC
10%, 50...60 Hz
permissible range: 110...240 V ± 10% / 50...60 Hz
Protection: 16 A K-characteristic
Controller idling current
max. 30 W when fully configured
External power supply (depending
on network): Terminal L1
According to supply voltage to terminal L
(secured on the circuit board: F200 / 4AT)
Control voltage / external supply 2
24 V
DC
regulated (
10% at nominal voltage 230 V)
Version
–A:
max. 250 mA
Version
–B / -C / -CX / -CGH / -CXGH / -LGH:
max. 500
mA
ncl. optional plug-in modules. Fuse protected by means of
self-resetting semiconductor fuse.
Short-circuit protected by central switching regulator.
Control voltage / external supply 3
for electronic limit switches and Safety edge
Nominal value 11.3V / max. 130mA
Controller inputs
Inputs 1
– 10 in
Version
–C / -CX / -CGH / -CXGH /
-LGH
Inputs 1
– 9 in
Version -A
24 VDC / typ.15 mA, max 26 VDC / 20 mA.
all inputs are potential free to join or:
<2 V: inactive logical 0
à
>10.5 V: inactive logical 1
à
min. Duration of input control commands: >
100 ms
Galvanic isolation using on-board opto-couplers
Input IN10
Version -B
Evaluation for slip door switch with 8,2 kΩ termination
resistor or is used as a second safety edge monitor.
Serial interface
RS485 A and B
only for electronic limit switches
RS485 le
vel, terminated in 100 Ω
Safety chain / E-STOP
terminals:
emergency-stop ext.31/32
and
41/42
all inputs must be connect free of potential
Contact rating:
26 V
DC
/
120 mA
in case the safety chain is interrupted, the drive cannot be
moved, not even under Deadman conditions
Not jumpered from the factory
Safety edge input:
For electrical safety edges with 1.2 or 8.2 kΩ terminating
resistor and for dynamic optical systems
Relay outputs
If inductive loads are connected (for example, additional
relays or brakes), these must be quipped with the
appropriate suppression measures (freewheeling diode,
varistors, RC elements)
Relay K1 and K2
Changeover contact free of
potential
• min. 10 mA
• Max. 230 VAC / 3 A
ATTENTION
Contacts used once for
circuit breakers cannot
switch further low
currents.
Digital Output OUT15
For version
–B/-C / -CX / -CGH / -
CXGH / -LGH
24 VDC / min. 10 mA / max. 120 mA
Generell application: All types of resistive, iinductive and
capacitive loads in industrial applications