Description
Possible reason for error
F.80B
Wrong Test of input B of the
stationary unit TST FSx
• Input B of the stationary unit was tested wrong
• The device which is connected to the input does not work correct
• The stationary unit is defective
F.80C
Wrong Test of input C of the
stationary unit TST FSx
• Input C of the stationary unit was tested wrong
• The device which is connected to the input does not work correct
• The stationary unit is defective
F.811
Wrong test for output 1 of the
stationary unit
• Output 1 of the stationary unit was tested incorrectly
• The cable between the stationary unit and the controller is damaged or not connected
• The stationary unit is defective
• Incorrect settings for parameter P.5xF, P.47b or P.465
F.812
Wrong Test for output 2 of
stationary unit TST FSx
• Output 2 of the stationary unit was tested incorrectly
• The cable between stationary unit and controller is damaged or not connected
• The stationary unit is defective
• Incorrect settings for parameter P.5xF, P.47b or P.465
F.813
Wrong Test of output 3 of the
stationary unit TST FSx
• Output 3 of the stationary unit was tested incorrectly
• The cable between the stationary unit and the controller is damaged or not connected
• The stationary unit is defective
• Incorrect settings of parameter P.5xF, P.47b or P.465
F.821
Wrong parameter setting input 1 of
mobile unit
• The device which is connected to input 1 of the mobile unit does not fit to the settings
• Check Parameter P.F1F
F.822
Wrong parameter setting input 2 of
mobile unit
• The device which is connected to input 2 of the mobile unit does not fit to the settings
• Check Parameter P.F2F
F.823
Wrong parameter setting input 3 of
mobile unit
• The device which is connected to input 3 of the mobile unit does not fit to the settings
• Check Parameter P.F3F
F.824
Wrong parameter setting input 4 of
mobile unit
• The device which is connected to input 4 of the mobile unit does not fit to the settings
• Check Parameter P.F4F
F.831
Disturbed input 1 of mobile unit
TST FSx
• The input 1 of the mobile unit is disturbed
• The connection to the device is interrupted
F.832
Disturbed input 2 of mobile unit
TST FSx
• The input 2 of the mobile unit is disturbed
• The connection to the device is interrupted
F.833
Disturbed input 3 of mobile unit
TST FSx
• The input 3 of the mobile unit is disturbed
• The connection to the device is interrupted
F.834
Disturbed input 4 of mobile unit
TST FSx
• The input 4 of the mobile unit is disturbed
• The connection to the device is interrupted
F.841
Frequency error on input 1 of
mobile unit
• The connected optical safety edge is faulty
F.843
Frequency error on input 3 of
mobile unit
• The connected optical safety edge is faulty