TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-L
FEIG ELECTRONIC GmbH
Page 42 of 71
FUZ2-A-B-C-CX-L_Montageanleitung_GB
_10.docx
Motor data P.100
– P.103
The door controller uses the following parameter setting to the learn about the type of motor being used.
Read the data from the nameplate and enter them into the corresponding parameters.
Manufacturer
Type designation
0,5 KW
50 Hz
Iso.Kl.: F
IP 55
Figure 35: Typical motor nameplate (may vary)
Be sure to note the Y/
wiring of the motor. The motor data must be entered in accordance
with the motor wiring. 400 V setting is not applicable, since the controller can source a
maximum motor voltage of 230 V.
U1
V1
W1
W2
U2
V2
L1
L2
L3
U1
V1
W1
W2
U2
V2
L1
L2
L3
Star wiring
Delta wiring
Figure 36: Star/Delta wiring
The automatic query of basic data can be interrupted by pressing the
OPEN button when the
controller is being turned ON. This causes a direct jump to the parameter configuration mode.
cos
0.85
P.101: Motor
current
P.102: Cos
P.100: Nominal motor
frequency
P.103: Nominal motor voltage
/ Y 2.4 / 1.4 A
/ Y 230 / 400 V