F.364
Safety edge
– testing failed
• Safety edge was not activated as expected when requesting a test.
• The time between request for testing and actual testing not in agreement
• The pre-limit switch is set incorrectly
F.365
Redundancy error with interruption
• One of the processing channels for interruption detection does not react identically with the second channel →
Controller board defective, if no other error message F.3xx is shown
• Dynamic optical system connected but not set in Parameter P.460
F.366
Too high a pulse frequency for
optical safety edge
• Defective optical safety edge
• Defective input for internal safety edge
F.369
Internal safety edge incorrectly
parameterized
• An internal safety edge is connected but deactivated → set P.460 to the used edge type
F.36A
Redundancy error of the 8K2 slip
door switch on the internal safety
edge evaluation unit
• One of the contacts of the redundant 8k2 slip door switch is defective
• The slip door was not fully opened or closed
F.371
Number of trips of the Safety input
E, normally this is the integrated
safety edge evaluation, has
reached set limit (configurable in
P.47E)
• Parameterized, maximum number of trips of the safety input E during a door cycle was exceeded → To reset
close the door in deadman mode
• Check the set number of trips in P.47E
F.372
Redundancy error with short circuit
• One of the processing channels for short circuit detection does not react identically with the second channel.
• Controller board defective
F.373
Fault in the safety edge (message
comes from module)
• Cable break to safety edge, no edge connected, edge termination resistor incorrect or defective
• Jumper for termination resistor definition in wrong position.
• Safety edge processing selected with Parameter P.470, but module not plugged in or wrong module.
F.374
Safety edge
– testing failed
• Pre-limit switch for safety edge incorrectly set or defective
• Processing module defective
• Safety edge defective
F.379
Safety edge detection defective
(coding pin or parameter setting)
• No module plugged in but was reported as present by a parameter
• The controller was started up with another module than the one currently plugged in
F.37A
Redundancy error of the 8K2 slip
door switch on the internal safety
edge evaluation unit channel 1
• One of the contacts of the redundant 8k2 slip door switch is defective
• The slip door was not fully opened or closed
F.380
Short circuit detected on safety
input
• Short circuit detected on edges with normally closed contact