TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-L
FEIG ELECTRONIC GmbH
Page 54 of 71
FUZ2-A-B-C-CX-L_Montageanleitung_GB
_10.docx
No.
Description
Possible reason for error
F.383
Interruption on safety input
• Connection cable defective or not connected
• Termination resistor incorrect or missing
• Jumper incorrectly set
F.384
Safety input
– testing failed
• Safety edge was not activated as expected when requesting a test.
• The time between request for testing and actual testing not in agreement
F.385
Fault in pre-limit switch for safety
edge
• Pre-limit switch for turning off the safety edge or reversing after safety edge tripping remains tripped even in the
upper end position.
F.386
Too high a pulse frequency for
optical safety edge
• Defective optical safety edge
• Defective input for internal safety edge
F.389
Safety input incorrectly
parameterized
• A safety edge is connected but deactivated
Safety input Jumper incorrectly set (as digital input jumpered but as safety edge set)
F.38A
Redundancy error of the 8K2 slip
door switch on the second internal
safety edge evaluation unit
• One of the contacts of the redundant 8k2 slip door switch is defective
• The slip door was not fully opened or closed
F.3A1
Number of trips for safety input A
has reached set limit
• Parameterized, maximum number of safety input trips during a door cycle was exceeded
F.3B1
Number of trips for safety input B
has reached set limit
• Parameterized, maximum number of safety input trips during a door cycle was exceeded
F.3C1
Number of trips for safety input C
has reached set limit
• Parameterized, maximum number of safety input trips during a door cycle was exceeded
F.400
Controller hardware reset detected
• Excessive noise on supply voltage
• Internal watchdog tripped
• RAM error
F.401
Watchdog Error
• Internal Watchdog has released
F.40A
Software Exeption
• Internal error detected
F.40B
Communication error expansion
board
• The communication between main board and expansion board is disturbed
F.40C
Unknown extension board (CAN
connection)
• Incorrect hardware coding of the extension board
• Control software does not support the expansion card
• Expansion card defective
F.410
Over-current (motor current or DC-
bus)
• Wrong motor data set (P.100 – P.103)
• Non-adjusted voltage increase / boost set
(P.140 or P.145)
• Motor not properly dimensioned for door
• Door sticks