
Diesel engine Series 15B / 18B
Operation
2008-09-08
57
Normal operation
Let the engine warm up for approx. 5 minutes after starting.
Increase load slowly.
Do not let the engine idle longer than 30 minutes and do not
operate without load (longer idling of the engine can result in
excessive carbonisation on the piston and cylinder barrel).
Continuous operation
Let the engine warm up for approx. 5 minutes after starting.
Increase load slowly.
Check the engine oil level every 15 hours during continuous
operation and refill with engine oil if necessary (see Chapter
Filling engine oil).
For this purpose:
z
Switch off the engine
z
Wait 5 minutes so that the oil can flow back from all bearings
into the oil sump or additional oil sump (for engines with
additional oil sump).
z
Check engine oil level and correct if necessary.
z
Start the engine again.
Pos: 7.23 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 75473
Pos: 7.24 /KN2006-Projekte/Bukh-Farymann/Bedienung/1.1
Abstellen 6415 @ 54\mod_1196698488440_2.doc @ 836876
7.6 Switching
off
CAUTION!
Risk of injury due to engine run-on!
After switching off, the engine runs on for approx.
10 to 20 seconds.
Therefore:
– Wait until the engine is at a standstill before
starting all work.
CAUTION!
Engine damage due to premature switching off!
Switching off under load can reduce the lifetime of
the engine.
Therefore:
– During full load operation, let the engine idle for
approx. 5 minutes without load before switching
off.