Figure 5. Connecting to the terminal strip connectors
Rack Mount Power Module Specific
Connect the remaining conductors to the circuit board via the terminal strips. The four 16 gauge conductors
fit into one terminal strip block. The two 12 gauge conductors fit into another terminal strip block. Follow the
color codes on the circuit board to ensure that each conductor fits into the correct receptacle. Note that the
12 gauge conductors fit very snug into the terminal strip block. Make sure that the strands of the conductor
are not separated. Otherwise it will be difficult to ensure a proper connection.
Mating the Connections
Connect the BNC and RJ-45 to their respective receptacles on the Power Module's circuit board. Follow the
labels on the pcb to ensure that each RJ-45 is connected to the correct receptacle. Prior to mating to the
circuit board, allow the cables to be coiled once to remove any strain as they come from the gland.
Figure 6. Minimize strain on wires - bulkhead mount Power Module