3.
16
(MT13 - En 2015)
1
2
3
4
5
6
7
8
9
3
2
5
5
2
3
PORTA
SERIALE
PERSONAL
COMPUTER
SPINA
STEREO
Ø = 2,5mm
Turn on the PC and then the push-button
panel.
Press the button PROG to enter the pro-
gramming mode.
Enter the code 05 and press the button
;
the display shows “TD2100PL ---- PC / in
progress....0”.
Download the names from the PC within 15
seconds; the display shows “TD2100PL ---
- PC / in progress....1”, “TD2100PL ---- PC /
in progress....2” and then the downloaded
names.
At the end of download the push-button
deletes the existing names. The first line of
the display shows “waiting” and the second
line shows a status bar to show the progress
of the deletion operation. At the end the
display shows “Programming / type: “.
Turn off the push-button panel and then the
PC.
Disconnect the cable from the PC and the
push-button panel.
Bring the jumpers J6 and J7 back to 1-2.
Ordering names (code 06)
You can list the names in alphabetical order
(from A to Z).
Press the button PROG to enter the pro-
gramming mode.
Enter the code 06 and press the button
;
the first line of the display shows “waiting”
and the second line shows a status bar; at
the end of the operation the push-button
panel returns automatically to the program-
ming mode (the display shows “Program-
ming / type: “ ).
Continue by entering the code of a new
programming function or press the button
PROG to exit.
Inserting the external door station
address PE (code 10)
You can code the external door station address
with codes from 231 to 250.
Press the button PROG to enter the pro-
gramming mode.
Enter the code 10 and press the button
;
the display shows "ADDRESS PE".
TD2100PL
Dial the coding number for the door station and
press the button
to confirm.
Continue by entering the code of a new program-
ming function or press the button PROG to exit.
Inserting the button address P1 (code 11)
To save an extension number and call it directly from
a button connected between terminals P1/P1:
press the button PROG to enter the programming
mode;
enter the code 11 and press the button
; the
display shows "ADDRESS P1";
dial the extension number. Extensions must be
coded with numbers from 001 to 200;
press the button
to confirm;
continue by entering the code of a new program-
ming function or press the button PROG to exit.
How to enter the address of EC-EM terminals
(code 12)
press the button PROG to enter the programming
mode;
enter code 12 and press the button
; the display
shows “ADDRESS EC”;
dial the number of the desired address (255 for
relay or camera activation mode; 250 for door
lock mode; number of internal station before the
first user of the supplementary door lock service);
press the button
to confirm programming;
press the button PROG to exit the programming
mode.
Operations whit door keeper exchangers
(code 30)
Following settings are necessary if in the system are
installed main and/or secondary door keeper
exchangers.
Press the button PROG to enter the programming
mode.
Enter the code 30 and press the button
; the
display shows "ADDRESS PDX".
Enter address 201 if the door station operates
with 1 or more main door keeper exchangers or
address 210 if the door station operates with 1 or
more secondary door keeper exchangers.
Press the button
to confirm.
Press the button PROG to exit the programming
mode.
press
to confirm; the display shows
“Programming / type: “;
continue by entering the code of a new
programming function or press the but-
ton PROG to exit.
Loading names from PC (code 05)
You can load names directly from your PC.
Load the names on the PC using a
dedicated software application (software
supplied on demand).
Turn off the push-button panel and the
PC.
Connect the PC serial port to the stereo
jack on the back of the push-button panel
with a cable as shown in the figure.
Move the jumpers J6 and J7 on the back
of the push-button panel from 1-2 to 2-3.
DOOR STATIONS
DIGITAL PUSH-BUTTON PANEL
Table 3.4 - System programming codes (code 03)
Programming
Function description
Default
Value entered with buttons
code
settings
= 0
= 1
bit 0
door lock activation time
3 sec.
3 seconds
6 seconds
bit 1
activation upon call from internal station (1)
YES
NO
YES
bit 2
door lock activation with (2)
NO
NO
YES
bit 3
deactivation of tone generator on the external door station
NO
NO
YES
bit 4
activation of personalised initial screen (3)
NO
NO
YES
bit 5
deactivation of FARFISA and activation of personalised text
NO
NO
YES
bit 6
EC-EM terminals for additional camera switching
NO
NO
YES
bit 7
activation time of the EC-EM terminals for supplementary lock
3 sec.
3 seconds
6 seconds
1) With this function, by pressing the
button and lifting the handset up (or pressing
in Zhero, Echos, myLogic models), you can start a
conversation with an external door station from any internal station (in case of multiple external door stations in parallel a conversation can be
started with the last external door station that has made the call) and activate the door lock by pressing the key
.
(2) This functions allows for quicker door lock activation by pressing rather than dialling the code 00+
. For example: press + password
+
.