![Farfisa AD2121CAG series Technical Manual Download Page 173](http://html1.mh-extra.com/html/farfisa/ad2121cag-series/ad2121cag-series_technical-manual_544905173.webp)
5.
21
(MT13 - En 2015)
5
e) Connection of 2 actuators connected on the same riser
line
. One actuator with input command (i.e.: a button or
sensor) and one actuator with output switching (i.e.: connec-
tion to relay to actuate staircase lights, electrical door locks,
etc.)
IN
COM
OUT
NA
NC
C
2281
LM
LM
load 12Vac;
12÷24Vdc - 1A
f) Connections coming from the actuator
- In stand-by the relay C and NA contacts are open; they are
closed when the actuator is activated.
DUO line
Attention: The IN port of actuator "1" and the output relay of
actuator "2" must be programmed with the same address.
line to external door stations or exchangers
line to video distributors
DV2420
DV2420
LM
LM
LM
LM
LM
LM
LM
LM
IN
IN
COM
COM
OUT
OUT
NC
NC
NA
NA
C
C
2281
2281
2221ML
2221S
LP
LP
LI LI
LO LO
LO LO
LI LI
127/230Vac
"1"
"2"
V
I
D
E
O
I
N
T
E
R
C
O
M
S
- How to activate a relay 1471 or 1471E or 1472 using the OUT
and COM commands.
Attention: you can only use these Farfisa relays and the
actuator must be suitably programmed.
HOW TO CONNECT THE DOORKEEPER EXCHANGER
1
The in/out connection on the doorkeeper exchanger from the door
station (PE) and the internal line (PI).
2
The doorkeeper exchanger connection from the door station (PE) and
the internal lines (PI) through the DM2421 distributor-switcher.
3
Connection of the doorkeeper exchanger to one of the DM2444 riser
distributor outputs.
Attention! Remove the imped-
ance between the 2 terminals
LO in the junction box of door-
keeper exchanger.
INSTALLATION NOTES
2281
1471-1471E-1472
LM
LM
IN
COM
OUT
NA
NC
C
1
3
6
7
5
230V
127V
0
PRS210
In every installation diagram the most suitable points for connecting the
doorkeeper exchanger are marked with a diamond. The number inside
indicates the usable types of connection from those shown in this section.
Attention! Program only the
F1 interval on the DM2421
distributor line L2 inserting the
address of the PDX2000
doorkeeper exchanger
(default 201).
Attention! Program the DM2444 distributor LO4 output inserting the address
of the PDX2000 doorkeeper exchanger (default 201). The other DM2444
inputs and outputs must be programmed following the indications on the
installation schematic.
PE
PE
PI
PI
LO3
LO2
LI4
LI3
LO3
LO2
LI4
LI3
LO
LO
LI
LI
LO4
LO4
DM2444
PDX2000
A
J
T
G
P
W
D
M
B
K
U
H
Q
X
E
N
C
L
V
I
R
Y
S
Z
F
O
1
4
7
2
5
8
0
3
6
9
PE
PI
L1
LP
L1
LP
LO
LO
LI
LI
L2
L2
DM2421
PDX2000
A
J
T
G
P
W
D
M
B
K
U
H
Q
X
E
N
C
L
V
I
R
Y
S
Z
F
O
1
4
7
2
5
8
0
3
6
9
PI
PE
LO
LI
LO
LI
PDX2000
A
J
T
G
P
W
D
M
B
K
U
H
Q
X
E
N
C
L
V
I
R
Y
S
Z
F
O
1
4
7
2
5
8
0
3
6
9
DUO
line
1
2 3
J1 = 2-3
1 2
3
J2 = 1-2
1
2 3
J2 = 2-3
load 12Vac;
12÷24Vdc - 1A