Si 51VM/32
MULTI-WAY SYSTEM CONNECTED TO ONE AUDIO-VIDEO EXTERNAL DOOR STATION, ADDITIONAL SUR-
VEILLANCE CAMERA AND ACTIVATION OF AUTOMATIC GATE BY MEANS OF ACTUATOR
V
I
D
E
O
I
N
T
E
R
C
O
M
S
Internal stations: VIDEOINTERCOMS (VC)
INTERCOMS (CT)
series Zhero
myLogicOne
ECHOS
EXHITO
EXHITO
EXHITO
...
ZH1262B
(1)
...
ML2002C
(1)
...
EH9262CT
(1)
...
EX3262C
(1)
...
EX3252C
(1)
...
EX352
(1)
...
ZH1262W
(1)
...
ML2083
...
EH9262CW
(1)
...
EX3262
(1)
...
WB3252
(1)
...
EX362
(1)
...
TA1260
...
WA2160T-W
...
9083
...
WB3262
...
TA3160
...
TA320
...
TA2160
...
WA9100T-W
...
TA3160
...
TA9160
CONVENTIONAL door stations with digital encoder (PE)
series AGORA'
PROFILO
MATRIX
1
VD2121CAG - AD2121CAG
(1)
1
VD2120CPL-AD2120CPL
1
VD2120CMAS
VD2121CAGL - AD2121CAGL
(1)
1
CD2131PL÷CD2138PL
(1)
1
CD2131MAS÷CD2134MAS
(1)
... AG100TS-AGL100TS
(1)
...
PL24S-PL228S
(1)
... MAS24S
(1)
... AG21-AGL21
...
PL20-PL50
... MAS20
... AG20-AGL20
...
PL72-PL73
... MA72-MA73
1
PL82÷PL89
1
MAS62-MAS63
1
PL92÷PL99
(2)
1
MA92-MA93
(2)
Door stations with digital keyboard (PE)
series PROFILO
MATRIX
1
VD2120CPL-AD2120CPL
1
VD2120CMAS
1
TD2100PL
(1)
1
TD2100MAS
(1)
1
PL72
1
MA72
1
PL82
1
MAS62
1
PL92
(2)
1
MA92
(2)
Other articles
...
DV2421P - Q
(
*
)
Video distributor with 1 output
...
DV2424P - Q
(
*
)
Video distributor with 4 outputs
...
DV2422A
(
*
)
Active video distributor with 2 outputs
1
2220S
Transformer
1
2221ML - 2221S
Line power supply
1
DV2420
Line distributor
1
2281
Actuator module
1
TVT
Surveillance camera (see catalogue)
...
FP
(3)
Floor push-button (optional)
1
PA
(3)
Door release button (optional)
1
SE
(3)
Electric door lock (12Vac-1A)
... According to the number of users (max. 50). For more users, increase the
risers (SI54VM12 diagram on page 5.39).
(
*
)
Choose the video distributor according to the model of videointercom
preferred; see table 5.6 on page 5.8.
(1)
Articles to be programmed.
(2)
Rain shelters are used in replacement of back boxes and hood covers.
(3)
Articles not supplied by ACI Farfisa.
Installation notes
- If you use more than 4 push-button modules (door station), you must power
the name-plate LEDs of the additional modules with an 12Vac supplemen-
tary transformer (see page 5.15).
- With this schematic a maximum of 50 internal stations can be used with a
maximum system distance of 150 metres.
- For the cross section and installation of the wires see table 5.3 on page 5.6.
- For the correct operation of the system, jumper J1 of all the video
distributors must be left in position 2-3 (open line). The line impedance is
determined by the video intercom connected to the LO output of the last
video distributor; if this output is not connected close it by positioning jumper
J1 appropriately. The line must not remain open (see page 5.8).
- We recommend to install all articles framed with a broken line in the same
switchboard.
Programming
After all the connections have been made and the system powered up,
proceed to programming the apparatus listed below in the order shown.
Door stations:
- First button address (encoder and additional button
modules)
- Enter the user names (digital keyboard)
Internal stations: - User address (see chapter 2)
- Activation of a button to turn on the surveillance camera
monitoring
- Activation of a button to enable the actuator
2281:
- Actuator address
To program the actuator 2281, with TD2100.., you must disconnect terminals
LO of DV2420 (see chapter 4). You must encode the actuator and a key of
the internal stations with the same code (from 211 to 220).
Possible extensions of the system
- Higher number of users (using the diagram SI54VM12 on page 5.39)
- Internal stations in parallel in individual apartments (see page 5.18)
- Increase the distance of the installation (see pages from 5.11 to 5.13)
- Application of actuators for various services (see page 5.20)
- Application of one or more keeper exchangers (see page 5.21)
Control switching ON from the videointercoms
From each videointercom you can see the entrance by pressing
(or
).
To switch on the surveillance camera, press:
-
again (series Exhito and Echos);
-
and then "monitor" (series Zhero);
- "menu" and then "camera" (series myLogicOne).
The control switching ON is not enabled when another videointercom is
switched on.
Operating mode.
The internal station will receive the call and, if the called user if a videointercom,
the display will turn ON and show the entrance. Lift the handset (or press
) to start the conversation and press the button
to actuate the door
lock.
To actuate the automatic gate, press the key chosen during the program-
ming.
For more detailed information on operation see the description of the
different products (chapters 2, 3 and 4).