4.
34
(MT13 - En 2015)
Select ringer tones and number of ringing
Doorkeeper exchanger can receive 4 different kinds of call (from door
station, from user, from another doorkeeper exchanger and local call
using a button connected between GN and A1). Operating in the
following way it is possible to select a different ringing tone for each call:
- select “Ringing Tones” and press
- from the list select the kind of
call which you want to change - press
- you will hear the actual
ringing tone, from the list select the desired ringing tone - press
-
you access a page on which is written the actual number of ringing, if you
want to change it erase the actual number and enter, with the keypad,
the new number (from 1 to 9) - press
- select “save” - press
.
Ringing Volume
Ringing volume is the same for all the kind of calls.
- To adjust it select “Volume” and press
- an
adjusting bar is displayed on the screen - with the
buttons
adjust the volume - press
- select “save” - press
.
Ringing Tones can be disabled choosing the lowest
level of volume in this menu or directly from the Device Manager menu.
Ringing volume can be also momentarily adjusted acting on the buttons
while receiving a call.
Display Backlighting
Select LCD Backlighting - press
- chose the
desired color from the list or create a new color -
press
- select “save” - press
.
Display Contrast
Select LCD Contrast - press
- an adjusting
bar is displayed on the screen, adjust the contrast
of LCD acting on the buttons or - press
-
select “save” - press
.
Advanced and System settings
Advanced and system settings are fundamental for the correct working
of the system, therefore they are accessible only entering a 4-digit
password. From the factory the password is 1234. It is advisable to
change it with a personal one (see chapter “Password changing” on
page 4.34).
Attention. It advisable to write down the new password and keep it in
a safe place; If you lose the password you must ask a new one directly
to ACI FARFISA.
Advanced
To access the advanced menu you should:
Press
- select “settings” - press
- select “advanced” - press
- enter the 4-digit password - press
- the following functions
will be listed: Password, Relay mode, Relay timing, Restore factory
settings, Clear all bookings, Delete list, Recovery Directory.
-Call from door station
Call from user
Call from swbd.
Ringtone type
Programming number of
ringer tones
1
- Badinerie
Nokia Tune
Mozart 40
Call from door station
Ringer tones volume
75%
- Red
Green
Blue
Display backlight
Display contrast
50%
Booking
Mode
- Settings
Menu
####
21.09.11
11.06
Display backlight
- Advanced
Display contrast
Settings
SERVICE MODULES
Changing Password
To change the password it is necessary: - select “Password” – press
- press
to erase the actual password –
enter the new 4-digit password - press
-
select “save” - press
.
New password in now stored.
Operating mode of the internal relay.
Relay inside the doorkeeper exchanger (terminal boards C, NC, NO)
can be used for:
- additional ringer for the incoming calls, a lamp signaller can also be
driven
- power-ON a CCTV monitor only during the calls from the door
stations
- bistable relay operated by the button
; when the relay is activated
the LED
will light-Up
- monostable relay operated by the button
; when the relay is
activated the LED
will light-Up, timing of relay should be set
according the instructions of chapter “Timing of internal relay”.
- remain activated when the doorkeeper excanger is switched to night
mode.
To set the operating mode it is necessary: - select
“Relay mode” - press
- select the requested
mode - press
- select “save” - press
.
Timing of internal relay
To set the activation time of relay, only when the relay operates as
“additional ringer tone” and “monostable”, it is necessary: - select
“Relay timing” – press
- press
to erase
the previous programmed activation time – enter
the new activation time in seconds (from 1sec to 99
sec.) - press
- select “save” - press
.
Others
To operate these functions the assistance of a Farfisa technician
is necessary.
- Save DUO Logs
- LED x debug
- Video always ON
Factory settings
To restore the factory settings and reset all the data previously
programmed (except the directory) it is necessary:
-select “Restore factory settings” - press
-
select YES to confirm or NO to exit - press
- select “save” - press
.
Clear all bookings
To cancel all the booking queue:
-select “Clear all bookings” – press
- select
YES to confirm or NO to exit - press
- select
“save” - press
.
Erasing completely the directory
To completely erase the directory:
-select “Delete list” - press
- select YES to
confirm or NO to exit - press
- select “save”
- press
.
Restoring the users’ in the directory
To restore the last erased directory:
-select “Recovery directory” - press
- select
YES to confirm or NO to exit - press
- select
“save” - press
.
Programming system
password
1234
- Addit.ringer tone
Monitor door station
Bistable
Relay mode
Programming relay time
activation
30
Restore factory set.
NO YES
Clear ALL bookings
NO YES
Delete list
NO YES
Recovery directory
NO YES