4.
22
(MT13 - En 2015)
SERVICE MODULES
Preliminary information
- The activation addresses of the outputs, as a rule, range from 211 to
230 and must match the addresses stored in the buttons (or contacts
for the myLogic series) of the videointercoms connected to the DUO
line.
- The selector from factory is programmed according to the instructions
in the chapter “Factory settings”; for any changes it is necessary to first
indicate whether the item must operate at 4- or 7-exchange and then
enter the operating modes and activation codes of the outputs.
Factory setting
- 4-exchange operating mode (simultaneous switching of outputs ).
- Address 211 for the cyclic and contemporary activation of the outputs
from 1 to 4.
- No address stored for the activation of the individual outputs.
- All outputs used (ON position of all the SW1 and SW2 micro-switches).
Programming mode steps
1 - Remove the cover to access the buttons and programming micro-
switches.
2 -Set the device to operate at 4 or 7 exchanges.
3 - Enter the activation codes of the outputs.
4 - Enable the only outputs connected.
1 - Remove the cover
2 - Programming of the operating mode to 4 or 7 exchanges
To change the operating mode of the device, it is necessary to:
- press and hold the OK button until the continuous lighting of the LEDs
RG1÷4 according to the current setting (all 4 LEDs if in 4 exchange
mode or only the LED RG1 if in 7 exchange mode);
- press OK to modify it and wait until the LEDs indicate the confirmation
of the new operating mode (continuous lighting of the LED RG1 if 7-
exchange; of the 4 RG1÷4 LEDs if 4-exchange);
- to exit the programming, press and hold SKIP until the LEDs RG1÷4
start to flash if 4-exchange or the sole LED RG1 starts to flash if 7-
exchange.
3 - Output activation address programming
The programming of addresses for enabling outputs has the following
path:
a) - Enter the programming mode
b) - Program the cyclic operation
c) - Program the individual outputs to enable individual in the following
order:
a) 4-exchange version: 1 A/B/D/E - 2 A/B/D/E - 3 A/B/D/E - 4 A/B/D/E
b) 7-exchange version: 1A/B - 2A/B - 3A/B - 4A/B - 2D/E - 3D/E - 4D/E
d) - Exit programming mode.
a) Enter the programming mode
- Hold down the SKIP button until the 4 LEDs RG1÷4 light up sequentially.
b) Program the cyclic operation
- The cyclic operation allows you to switch the outputs by pressing one
single button from the videointercom. Each press will sequentially
enable the activated outputs (see section “Activation/deactivation of
the outputs”) starting from 1A/B to 4D/E (if 7-exchange) or 1A/B/D/E
to 4 A/B/D/E (if 4-exchange); by continuing to press, it restarts from the
output 1 A/B.
To enter or disable the address use one of 3 methods described in the
section “how to enter addresses while programming” then exit as
described in the section “exit the programming mode” or press SKIP
to switch to the programming of selective addresses for the outputs 1A
and 1B (with 2D and 2E if 4-exchange); the 4 LEDs RG1÷4 will light
up steadily.
How to enter addresses while programming
To enter addresses, you can follow one of the following 3 procedures:
- send the address to be stored in the selector by pressing the button
of the videointercom previously programmed with this address;
confirmation of storage is indicated by the temporary power OFF
and subsequent sequential power ON (cyclic programming) or fixed
power ON (individual programming) of the 4 LEDs RG1÷4;
- via the micro switches SW1 and SW2 compose the address to be
stored (the same address previously assigned to the button of the
videointercom or of all videointercoms enabled). For the codes
see table 4.8;
- press OK; confirmation of storage is indicated by the temporary
power OFF and subsequent sequential lighting (cyclic program-
ming) or fixed lighting (individual programming) of the 4 LEDs
RG1÷4;
- compose the address to be stored on the front panel keypad or the
doorkeeper exchanger and press the Enter key; confirmation of
storage is indicated by the temporary power OFF and subsequent
sequential lighting (cyclic programming) or fixed lighting (individual
programming) of the 4 LEDs RG1÷4.
Attention. If you do not want the
cyclic operation or enabling for
one or more outputs, while
entering the addresses, in the
corresponding position, store the
code 000 by setting all micro
switches SW1 and SW2 to OFF position and pressing OK to confirm.
000
SW2
SW1
ON
ON
1
1
2
2
3
3
4
4
+
OK
Table 4.8
Cross-reference between codes and microswitches position
of SW1 and SW2.
216
217
218
219
220
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
211
212
213
214
215
SW2
SW1
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
221
222
223
224
225
SW2
SW1
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
226
227
228
229
230
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4