![Farfisa AD2121CAG series Technical Manual Download Page 62](http://html1.mh-extra.com/html/farfisa/ad2121cag-series/ad2121cag-series_technical-manual_544905062.webp)
2.
52
(MT13 - En 2015)
INTERNAL STATIONS
EX362
. White colour intercom with integrated
coding, 8 push-buttons, electronic microphone
and spiral cord.
Wall-mountable with expansion plugs or wall
box or on the table with the TA320 adaptor.
Technical characteristics
Power supply directly from the line
Stand-by current:
8mA
Operating current:
0.1A
Operating temperature:
0°÷+50°C
Maximum admissible humidity: 90%RH
Terminals
LM/LM Line inputs
A1
Floor call positive in-
put
GN Floor call negative in-
put
GC Additional actuator
positive output
GE Additional actuator negative output
INTERCOM
83
3
"
4
/
1
62
2
"
16
/
7
218
8
"
16
/
9
EXHITO
SERIES
3
1
J1
4
2
A1 GN GC GE LM LM
Jumper the closing impedance
The intercom are provided with the jumper J1
that, when placed in the correct position, allows
to adapt the signal from the riser.
J1
Jumper to select impedance termi-
nation line
1-2
termina-
tion 100
Ω
Ω
Ω
Ω
Ω
(default)
83.5
3
"
4
/
1
172,5
6
"
16
/
13
TA320
. Table adapter complete with junction box and 2.4m
connection cable with 20 wires.
LM
LM
GE
GC
GN
A1
P
EX362
Yellow
Junction box
LM
LM
LM
- Remove the cover to the junction box.
- Make the connection on the
intercoms terminal boards and write
down the correspondence between
terminals and wire’s colour on the
label on the junction box.
- Connect the wires of the system to the
terminals of the junction box.
Table version
1 2 3 4
1 2 3 4
1 2 3 4
INSTALLATION
Flush mounted version
1
3
2
1. Red LED. Ringer OFF
2. Green LED. Conversation in progress
3. Yellow LED. Indicates the status of services of
the actuators
Signalling LEDs
2-3
termina-
tion 15
Ω
Ω
Ω
Ω
Ω
3-4
o p e n
line