- 40 -
I
T
ALIANO
E
NGLISH
F
RANÇAIS
E
SP
AÑOL
P
ORTUGUÊS
D
EUTSCH
Mi 2425
PROGRAMMING
Following is a list of default settings. If necessary,
follow the instructions contained in the next chap-
ters to change them.
Factory setting
-
External Door Station Address = 231
- Address associated with First Button = 100
- Address associated with First Button of first
additional push-button panel = 102
- Lock actuation time = 3 seconds
- Buttons with special functions = none
Entering the programming mode
Remove the plate.
Move the jumper J1 from position 1-2 to 2-3;
you hear the programming tone and the red
LEDs turn ON (R).
Entering codes or addresses
- Codes and/or addresses must have three digits
(hundreds, tens, units); codes and/or addresses
with tens and units or units only must be
completed by adding zeros. For example,
address 96 becomes 096 and address 5
becomes 005.
- Enter one digit at a time by pressing the “P1”
button for a number of times “n”, where “n” is the
value of the digit you want to enter, followed by
a pause of about 2 seconds before you go to
the next digit (a tone on the
loudspeaker
will tell
you when to go to the next digit). The maximum
value you can enter is 255. For example, to
enter code 096 you must:
- press the “P1” button 10 times to enter digit
0 and wait for 2 seconds until you hear a tone in
the
loudspeaker
.
- press the “P1” button 9 times to enter digit 9
and wait for 2 seconds until you hear a tone on
the
loudspeaker
.
- press the “P1” button 6 times to enter digit 6
and wait for 2 seconds until you hear a tone on
the
loudspeaker
.
Note: - remember to confirm the codes you have
entered as explained in the programming
chapters.
Table 1
Programming codes
111 External Door Station address
112 First Button address (Pn of VD2121CAG
external door station)
113 address of first button of first Additional
Push-button Panel (Pn of the first
AG100TS)
114 door lock activation time
121 system programming (see table 2)
210 programming of call button with camera
deactivation during the call
211 button reset with camera deactivation during
the call
233 programming the buttons with special
functions
000 back to factory settings
Programming procedure
To make the programming it necessary to:
a) enter the programming mode following the
instructions described in “
Entering the
programming mode”;
b) enter the three digits of the programming
code you want to change following the
instructions contained in “
Entering codes or
address”; press PN to confirm: you hear the
confirmation tone and the red LEDs start
flashing.
c) make the operations described in the
specific programming chapter.
d) continue with another programming operation
or exit moving the jumper J1 from 2-3 to 1-2.
Entering the External Door Station address
(
code 111)
In this mode you can code the external door
station address with codes from 231 to 250.
Enter the programming mode following the
instructions described in “
Entering the pro-
gramming mode”;
Enter code 111 and press Pn; you hear a
confirmation tone and the red LEDs start flash-
ing.
2-3
Programming
mode
1-2
Operating mode
push-button Pn
push-button P1
Exit the programming mode
To exit the programming mode, you must bring
the jumper J1 from position 2-3 back to position
1-2.
Using the push-buttons for programming
Press button "Pn" and "P1" to enter addresses
or codes.
Pn:
Press this button to confirm code
programming or go to the next
programming step.
P1:
Press this button to increase the value
you want to enter. Press the button for a
nu
mber of times equal to the digit you want
to enter (digit 1 = 1 time; digit 9 = 9 times;
digit 0 = press “P1” 10 times).
The pressure of the “P1” button is confirmed by
an acoustic tone on the loudspeaker.
Dial the code number you have chosen for the
external door station and press Pn to confirm;
you hear the confirmation tone and the red
LEDs go back ON without flashing.
Continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J1 to position 1-2.
Entering the First Button address
(code 112)
The VD2121CAG board has 2 buttons: PN and
P1. PN is the first button and P1 takes the next
value (i.e.: Pn = 001, P1 = 002; Pn = 058, P1 =
059).
The first button (Pn) is coded by default with
address 100; if you want to change it, you must:
enter the programming mode following the
instructions described in “
Entering the pro-
gramming mode”;
enter code 112 and press Pn; you hear a
confirmation tone and the red LEDs start flash-
ing;
dial the address you want to assign to Pn.
Extensions must be coded with numbers from
001 to 200;
press Pn; you hear a confirmation tone and the
red LEDs go back ON without flashing;
c
ontinue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J1 to position 1-2.
Entering the address of the First Button of
the first additional push-button panel (
code
113).
To increase the number of calls, you must
integrate the VD2121CAG external station with
one or more additional AG100TS push-button
panels (max. 16). Each additional push-button
panel must be coded with the 4 microswitches
provided on the board (see instructions attached
to the product). Moreover, an address must be
assigned to the first button of the first additional
push-button panel. The next buttons of all the
additional push-button panels will automatically
take progressive numbers. This address must
be higher than the address of the P1 button of the
VD2121CAG external door station.
The first button (Pn) of the first additional
AG100TS push-button panel is coded by default
with address 102; if you want to change it, you
must:
enter the programming mode following the
instructions described in “
Entering the pro-
gramming mode”;
enter code 113 and press Pn; you hear a
confirmation tone and the red LEDs start flash-
ing;
dial the address you want to assign to the Pn
button of the first additional push-button panel.
Addresses must be numbers from 001 and
200; remember that addresses 100 and 101
are assigned to the 2 VD2121CAG buttons by
default;
c
ontinue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J1 to position 1-2.
Lock actuation time (
code 114). To change
the lock actuation time, you must:
enter the programming mode following the
instructions described in “
Entering the pro-
gramming mode”;
enter code 114 and press Pn; you hear a
confirmation tone and the red LEDs start flash-
ing;
R
R