Installation
8.
310
· 288 ·
Ref.1912
DDS
HARDWARE
Heat dissipation
The external Ballast resistors can generate a great deal of heat. That's why,
sometimes, depending on the temperature of the installation area, it may be
necessary to evacuate the heat by means of fans.
See an example with data on the temperatures reached in points of the top
of the module and the effect of the fan:
INFORMATION.
If a fan is required due the conditions of the location where
the resistor will be installed, remember that FAGOR offers external ballast
resistors with fan.
i
T. H8/3
Temperatures reached in the points defined earlier in the figure
. *Temperature variation due to the effect of the fan (PAPST
614). Temperature in °C (conversion: °F=32+1.8 °C).
Dissipated power (W)
734
896
1042
1400
1400
*
Ambient temperature (°C)
25
22
24
24
24
T1 (°C)
90
89
115
138
74
T2 (°C)
157
170
185
217
113
T3 (°C)
80
79
88
104
64
T4 (°C)
60
68
72
82
46
T5 (°C)
50
54
57
65
47
T6 (°C)
40
40
44
45
44
F. H8/21
Location of the temperature measuring points.
5
6
3
4
2
1
65 cm
30 cm
10 cm
25.6"
11.8"
3.93"
Summary of Contents for DDS Series
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......