Auxiliary modules
AUXILIARY MODULES
Auxi
liary pow
er
su
pply. APS-2
4
4.
Ref.1912
· 195 ·
DDS
HARDWARE
Status indicator lamps
The auxiliary power supply APS-24 has the following indicator lights that
inform about its running status.
OVER VOLTAGE.
Red LED. Output over voltage. It has exceeded 28 V
DC and interrupts its operation.
OVER CURRENT.
Red LED. Output over current. The power supply
has exceeded 10 A and its output voltage is less than 24 V DC.
ON.
Green LED. It is working fine.
RESET.
When the power supply quits working due to over voltage, the
RESET button may be used to restart the system.
Other considerations
Chapter
shows the strict rules that must be followed to
properly install the auxiliary power supply. Chapter
this manual shows their dimensions.
RESET
OVER VOLTAGE
OVER CURRENT
ON
WARNING.
This APS-24 auxiliary power supply is to be used to supply to
the electrical control circuits and signals to run the drive.
This module must
never be used to supply power to the holding brake of a motor.
The
holding brake may generate voltage peaks that could damage the unit.
Summary of Contents for DDS Series
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......