Selection criteria
5.
Ref.1912
· 213 ·
DDS
HARDWARE
Then, considering the peak power (S3-5% cycle) that some motors may request sometime:
T. H5/6
Selection of the power supply considering the peak power (S3-5% cycle) supplied by the drive
for IGBT switching frequencies of 4 kHz and 8 kHz.
SYNCHRONOUS FXM/FKM
Peak power P (S3-5%)
P (S3-5%)
(kW)
GROUP I
0 to 2 kW
synchronous
1
2
Sum of GROUP I
*
Ki
3
+
GROUP II
2 to 8.5 kW
synchronous
1
2
Sum of GROUP II
*
Kii
3
+
GROUP III
8.5 to 27 kW
synchronous
1
2
Sum of GROUP III
*
Kiii
3
=
SUM OF POWER (kW)
3
Nr of synchronous
motors per group
K
factor
AXD
drive
Power
(S3-5%)
1
1
AXD 1.08
5.2
2
0.63
AXD 1.15
9.8
3
0.50
AXD 1.25
16.4
4
0.38
AXD 1.35
23.0
5
0.33
AXD 2.50
32.9
6
0.28
AXD 2.75
49.3
AXD 3.100
65.8
AXD 3.150
98.7
in kW
V
= 400 V AC
Ip
= Imax of the drive that governs the motor
cos
= 0.95
POWER S3-5%
3 V I
P
cos
=
Summary of Contents for DDS Series
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......