Selection criteria
5.
Ref.1912
· 221 ·
DDS
HARDWARE
T. H5/14
Selection of the power cabling.
POWER CABLE FOR MAINS CONNECTION
Vmains: Line voltage
AXD/SPD:
400/460 V AC
ACD/SCD:
400/460 V AC
ACD/SCD ... - L
: 200/240 V AC
Rated current through the mains cable
MAINS POWER
COMPACT AXIS DRIVES, ACD:
COMPACT SPINDLE DRIVES, SCD:
Power cable
Power cable
In Amperes
Model
In Amperes
Model
C
13.1
MPC-4x1.5
40.0 < C
54.0
MPC-4x16
13,1 < C
17.4
MPC-4x2.5
54.0 < C
70.0
MPC-4x25
17.4 < C
23.0
MPC-4x4
70.0 < C
86.0
MPC-4x35
23.0 < C
30.0
MPC-4x6
86.0 < C
103.0
MPC-4x50
30.0 < C
40.0
MPC-4x10
103.0 < C
130.0
MPC-4x70
The purchase order must indicate the length of the cables.
4
(kW)
· 1000 / (
3 · V
mains
)
=
A
C
Rated current on FXM|FKM servomotors
=
A
C
Max. current on FM7|FM9 motors
=
A
C
Conductor section calculated for the B2 installation method, according to UNE-EN 60204-1:2007.
Summary of Contents for DDS Series
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......