Power supplies
2.
Ref.1912
· 77 ·
DDS
HARDWARE
The following figure shows the regenerative regulated power supply RPS-45 and its connector layout:
F. H2/37
Regenerative regulated power supply, RPS-45. Connectors.
1.
Power connector for the three-phase mains.
2.
Line voltage input connector for synchronism.
3.
Ground connection for the mains cable.
4.
Power DC BUS supplying power to the modular drives through metal bars.
X1.
Connector of the integrated auxiliary three-phase power supply with line voltage.
X2.
Output connector of the auxiliary 24 V DC power supply integrated into the module.
X3.
Connector to be used to open/close the main internal contactor (NS1-NS2 pins) and acknowledge
externally the status of the contactor (LINE CONTACT pins).
X4.
Connector to communicate with the modular drives through the internal bus.
X6.
Connector for the basic control signals.
top view
4
4
X2
X4
X3
3
1
X1
CAUTION.
AC touch current greater than
3.5 mA. Install ground wire of at least 10
mm² (Cu) or 16 mm² (Al).
L1 L2 L3
2
X6
Summary of Contents for DDS Series
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......