Installation
8.
310
· 280 ·
Ref.1912
DDS
HARDWARE
How to install AN exter nal Ballast resistor with inter nal
thermostat and with no fan
WARNING.
On top of the ER+TH modules, the air temperature can reach
values over 120°C/248°F. Therefore, the resistor should be mounted away
from the rest of the modules or even outside the electrical cabinet, always
vertically and away from cables and other temperature sensitive material.
F. H8/14
Installing AN external Ballast RESISTOR with internal thermostat and with
no fan.
Ballast resistor connection terminals.
Tk connection terminals of
the internal thermostat.
Always install it vertically
Re
L+
Diagram
Connect as shown in the image either one of
the two pins to + 24 V DC of the external power
supply of the electrical cabinet and the other
one to a PLC input.
Important. Remember to manage the chosen
PLC input in the PLC program to generate an
error when exceeding the limit temperature
(160°C) detected by the sensor and to open
the contact.
Connect as shown in the image the Ballast resistor terminals to the Re and L+
terminals of the terminal strip of the Ballast of the power supply or compact
drive accordingly.
Summary of Contents for DDS Series
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......