programming measures function
coffee
Press the icon
.
Press one of the coffee keys (ex.
Group 3).
The icons of the programmable keys
are shown on the services display.
TEST. By pressing the
key, the dispensing starts
and the following screen appears on the services display:
The parameters displayed are:
Dv
:
Volumetric meter incremental counter
tG
:
dispensing time
TB
:
instant coffee boiler temperature
RB
:
% activation coffee boiler
resistance
p
:
service
boiler pressure
Rc
: service
boiler resistance
Sl
: service
boiler water level
Evc
: service
boiler load solenoid valve
When one of the coffee keys is pressed (e.g. the
key), the
following parameters are displayed on the services display:
Water dose;
pre-infusion time;
saturation time.
The key in question will remain highlighted on the unit
display.
All the parameters can be adjusted by the user:
water dose (using the keys
);
pre-infusion time (using the keys
);
saturation time (by pressing the
icon, this will turn
into allowing the time to be adjusted with the keys
.
Press the
icon to exit the settings menu).
Press the
icon to confirm the information entered.
NOTE ExAMPLE
:
shows the duration in seconds of the
pre-infusion phase.
shows the duration in seconds of the
saturation phase.
NOTE. THE
key can also be programmed as DOSED:
press the
icon on the parameter display screen:
Press the
icon to return to CONTINUOUS mode.
The other functions of the
key will remain unchanged
in both configurations.
02_E71_E.indd 21