Output Checking
4
-6
1.3 Print Quality Improvement
1
Temperature of nozzle and bed
Proper temperature of the nozzle and bed depends on the material such as PLA and ABS.
The output quality may vary depending on the environment (temperature and humidity) during printing.
There is no absolute value of a proper temperature. You need to find a proper temperature by changing temperature
conditions. Temperature conditions can be changed in the Slicer program.
Material
Proper Temperature of Nozzle
Proper Temperature of Bed
ABS
230
C
~ 250
C
70
C
~ 80
C
ASA
230
C
~ 250
C
70
C
~ 80
C
RSA
230
C
~ 250
C
70
C
~ 80
C
PLA
190
C
~ 210
C
50
C
~ 60
C
2
Bed leveling
If an output is not properly attached to the bed or is too closely to the bed, try the followings:
①
See “5-1.4 Flexible Bed and Nozzle Cleaning” to clean the bed surface and the tip of nozzle.
②
See “2-2.4 Bed Leveling” to level the bed.
③
Once the bed is completely leveled, see “2-2.4 Z-Offset” to check the gap between the tip of nozzle and the
bed. If the gap is too wide or too narrow, adjust the gap.
3
Print model modification
The output quality may vary depending on the print model shapes.
To get the best quality, change the model shape or the print direction, or adjust the print conditions in Slicer.
4
Summary of Contents for A530
Page 8: ......
Page 26: ......
Page 27: ...Preparation for Use 1 type A530 ...
Page 39: ...UI Menu Description 2 type A530 ...
Page 71: ...Print 3 type A530 ...
Page 76: ......
Page 77: ...Output checking 4 type A530 ...
Page 83: ...Maintenance 5 type A530 ...
Page 104: ...Maintenance 5 22 5 4 Close the top door ...
Page 111: ...5 29 Maintenance 5 4 Pull the nozzle core forward and lift it up to remove it ...
Page 116: ......
Page 117: ...Appendix 6 type A530 ...