5
-27
Maintenance
5
4.4 Nozzle Change
Caution
- When the nozzle is heated, the parts are very hot. Be careful of burns.
- Be careful not to damage internal parts during replacement work.
Important
- Before replacing the nozzle, unload the filament.
It is recommended to replace the nozzle when the power is turned off for safety.
1
Separate the bellows fixed to the X-axis driving part.
Bellows
2
Place the replacement nozzle in the center of the X-axis driving part, and open the door in front of the nozzle.
Summary of Contents for A530
Page 8: ......
Page 26: ......
Page 27: ...Preparation for Use 1 type A530 ...
Page 39: ...UI Menu Description 2 type A530 ...
Page 71: ...Print 3 type A530 ...
Page 76: ......
Page 77: ...Output checking 4 type A530 ...
Page 83: ...Maintenance 5 type A530 ...
Page 104: ...Maintenance 5 22 5 4 Close the top door ...
Page 111: ...5 29 Maintenance 5 4 Pull the nozzle core forward and lift it up to remove it ...
Page 116: ......
Page 117: ...Appendix 6 type A530 ...