Setting the number of individual
ing stages
clean
Parameters [r40 to r4 ] are used to determine whether and how often each individual
9
cleaning stage is run. The parameters for the deactivated cleaning stages are hidden.
Acting on the temperature of the tank walls
It is possible to repeat the hot cleaning stages in order to warm up a cold tank. At the
end of cleaning, additional cold rinses can be used to cool down the tank again.
Setting the cleaning cycle so as automatically to have a certain number of alkaline
washes to one acidic wash
Parameter [r45] is used to determine whether the cleaning cycle generally includes
one or two main rinses.
[r45 = 1] - per cleaning cycle 1 alkaline
/ 1 acidic
wash
wash
[r45 = 0] - an acidic clean follows after x alkaline cleaning cycles.
Set “x” in [r21].
.16 Configuration of the different cleaning stages
9
.15
9
Detergent injection position
Parameter [r20] is used to determine whether the detergent is added in programme
stage D1 or D2
.
or in the feed container
Note: When filling the pre-hopper [r20 =0] the detergent is added when water is taken
for the second time.
See section
- Cleaning programme diagram
6.2
In position D2 there is a risk that a pressure peak (caused by the simultaneous start of
detergent injection) may cause a highly concentrated water-detergent mixture to pass
through the manhole to the outside of the tank.
on