Number of passes of seperate cleaning stages
Range
Default
r40 Number of passes clean. stage 0: Rinse out
0 .. 5
0
r41 Number of passes clean. stage 1: Pre-rinse 1
0 .. 5
1
r42 Number of passes clean. stage 2: Pre-rinse 2
0 .. 5
1
r43 Number of passes clean. stage 3: Main rinse 1
1
1
(not changeable)
r44 Number of passes clean. stage 4: Interm
. rinse 1
ed
0 .. 5
1
r45 Number of passes clean. stage 5: Main rinse 2
0 .. 1
0
r46 Number of passes clean. stage 6: Interm
. rinse 2
ed
0 .. 5
1
r47 Number of passes clean. stage 7: isinfection
D
0 .. 1
0
r48 Number of passes clean. stage 8: fter-rinse
A
0 .. 5
0
r4 Number of passes clean. stage : inse
9
9 R
out
0 .. 5
0
Selection of water valve (cold / hot water)
Range
Default
r50 Valve selection clean. stage 0: Rinse out
1 .. 4
1
r51 Valve selection clean. stage 1: Pre-rinse 1
1 .. 4
1
r52 Valve selection clean. stage 2: Pre-rinse 2
1 .. 4
3
r53 Valve selection clean. stage 3: Main rinse 1
1 .. 4
2
r54 Valve selection clean. stage 4: Intermitt. rinse 1
1 .. 4
1
r55 Valve selection clean. stage 5: Main rinse 2
1 .. 4
1
r56 Valve selection clean. stage 6: Interm
. rinse 2
ed
1 .. 4
1
r57 Valve selection clean. stage 7: isinfection
D
1 .. 4
1
r58 Valve selection clean. stage 8: After-rinse
1 .. 4
1
r5 Valve selection clean. stage : inse
9
9 R
out
1 .. 4
1
1: Cold water
2: Warm water
3: Cold and arm water (mixed)
w
4: Hot water
5: H
and cold water
ot water
6: H
and warm water
ot water
7: H
and warm water and cold water
ot water
Selection of drain valve
Range
Default
r60 Drain valve select. clean. stage 0: Rinse out
1 .. 2
1
r61 Drain valve select. clean. stage 1: Pre-rinse 1
1 .. 2
1
r62 Drain valve select. clean. stage 2: Pre-rinse 2
1 .. 2
1
r63 Drain valve select. clean. stage 3: Main rinse 1
1 .. 2
1
r64 Drain valve select. clean. stage 4: Interm
. rinse 1
ed
1 .. 2
1
r65 Drain valve select. clean. stage 5: Main rinse 2
1 .. 2
1
r66 Drain valve select. clean. stage 6: Interm
. rinse 2
ed
1 .. 2
1
r67 Drain valve select. clean. stage 7: isinfection
D
1 .. 2
1
r68 Drain valve select. clean. stage 8: After-rinse
1 .. 2
1
r6 Drain valve select. clean. stage : inse
9
9 R
out
1 .. 2
1
1: Drain valve 1
2: Drain valve 2
8.5 Level “Extended cleaning parameters” (r parameters)
8. Setting of parameters
From option 4 onwards, the
function A 16 (hot water valve)
must additionally be assigned
to one of the relays in the A
parameters.
In case of selection , the
2
function A 1 (
valve) must
5 drain
additionally be assigned to one
of the relays in the A
parameters.
Page 56
Summary of Contents for DARI-KOOL GALA-KOOL Pro
Page 29: ...Page 29...