6. Cleaning
6.3 Explanation and programming of the cleaning process
Page 24
Cleaning agent dosing: (see also explanation two pages before)
Depending on the setting of the parameter [r20], detergent is injected at the end
of the water intake time [n32] or the subsequent water intake time [n33] as fol-
lows:
If ‚cleaning stage 5' is activated [r45=1] only alkaline detergent is injected here
for duration [n101*].
If 'cleaning stage 5' is deactivated [r45=0] alkaline detergent is injected x
times for duration [n101*] before acidic detergent is injected once for duration
[n102*].
The number of alkaline cleaning cycles is set in [r21].
If a heater is present [r35], this is switched on. When the heating temperature
[n106] is reached, the heater is switched off again.
If the temperature is not reached within the pre-set time [r37], the control unit
continues with the program, but a fault report is displayed at the end. See sec-
tion .5.3 - F44
7
If a switch-on delay [r36] has been parameterized for heating, heating starts
only after this time has elapsed. (This is to ensure that water is in the heater.)
Main circulation time: The water circulates for the pre-set time [n34]. During the
main circulating time, a post-heating temperature [n109] can be defined.
An additional time can be defined in parameter [n35], in which the drain valve
opens (agitator and cleaning pump continue to run)
Agitator and pump switch off.
Drain valve opens for the pre-set time [n36]. See also [n35].
Cleaning stage 4
: INTERMEDIATE RINSE 1
Parameter [r44] = 0
‘Cleaning stage 4’ disabled
Parameter [r44] = 1..5
‘Cleaning stage 4’ execute x-times
In case of cleaning method 'green' – it is set in programme step [n 0] how often
5
the feed container is filled with water up to level 2 and water is pumped back up
to level 1. As long as the rinsing pump is running, the drain valve is open.
Water is taken in.
The parameter [n41] is used to stipulate whether water will be taken by level or
time.
If time-controlled, the water intake time is defined in parameter [n42].
The cleaning parameter [r54] is used to stipulate whether cold, hot or mixed
water is to be taken in.
If, in the event of intake by level, the level is not reached after a pre-set time
[r32], the cleaning cycle is interrupted. See section .5.3 - F44
7
Agitator and pump start to run.
Another option is to select an 'additional water intake time' using [n43].
The water circulates for the pre-set time [n44].
An additional time can be defined in parameter [n45], in which the drain valve
opens (agitator and cleaning pump continue to run)
Agitator and pump switch off.
Drain valve opens for the pre-set time [n46]. See also [n45].
In case of green
n32
n33
and
have to be
parameterized on „0“
In case of green
n41
n42
and
have to be
parameterized on „0“
In case of green
n43
n44
and
have to be
parameterized on „0“