Test digital inputs
All inputs [o.21 to o.28] can be selected via the arrow keys and tested as follows:
Select the desired parameters with the arrow keys.
Press the SET key briefly: '0' or '1' appears in the display (depending on the
current switching state of the respective component).
Change switch state (e.g. safety switch).
The display toggles between '0' and '1'.
Press the SET key again: The display shows the current parameter name again.
Range
Default
o.21 Test digital input 1
0 .. 1
- - -
o.22 Test digital input 2
0 .. 1
- - -
o.23 Test digital input 3
0 .. 1
- - -
o.24 Test digital input 4
0 .. 1
- - -
o.25 Test digital input 5
0 .. 1
- - -
o.26 Test digital input 6
0 .. 1
- - -
o.27 Test digital input 7
0 .. 1
- - -
o.28 Test digital input 8
0 .. 1
- - -
o.29 Test of external digital input 1
0 .. 1
- - -
o.30 Test of external digital input 2
0 .. 1
- - -
o.31 Test of external digital input 3
0 .. 1
- - -
o.32 Test of external digital input 4
0 .. 1
- - -
o.33 Test of external digital input 5
0 .. 1
- - -
0: switched
1: unswitched
Test level inputs
Range
Default
o.41 Level 1
-10 .. 10
0
o.42 Level 2
-10 .. 10
0
-1 : less sensitive
0
0: normal
1 : more sensitive
+ 0
Adjust sensitivity: green LED "OK" lights up if 4
4
o. 1 / o. 2 detects level
Display
capacity
agitator
o.70 test of relay on optional ESVAW 002 or 003
o.71 agitator 1
in watt
o.72 agitator 2
in watt
Display of the Software version
o.98 Display of the Software version