7.6
Accessory Wiring
Photo Eye, Safety Edge, Safety Loop:
Normally Closed (NC) of safety device
= Photo terminal of PHOTO block on gate opener contr ol boar d.
Common (COM) or Ground (GND) of safety device
= GND terminal of PHOTO block on gate opener con-
trol board.
12V Power positive (+) or (12V) or (PWR) of safety device
= V+ terminal of PHOTO block on gate opener
control board.
12V Power Negative (-) or (GND) or (PWR) of safety device
= GND terminal of PHOTO block on gate open-
er control board.
*Remove safety jumper from PHOTO terminal if using a safety device.
*12V is not a misprint, the V+ terminal has a 12V output.
Solenoid Gate Lock:
Positive Lead of lock
= A terminal of E_LOCK block on gate opener contr ol boar d.
Negative Lead of lock
= B terminal of E_LOCK block on gate opener control boar d.
Magnetic Gate Lock:
M agnetic gate lock s must have their own power supply and their own
relay.
Coil of relay for magnetic lock
= A terminal of E_LOCK block on gate opener contr ol boar d.
Coil of relay for magnetic lock
= B terminal of E_LOCK block on gate opener contr ol boar d.
Connect positive lead of the power supply directly to the positive lead of the mag lock.
Connect negative lead of the power supply to the N/C terminal of the relay.
Connect the COM terminal of the relay to the negative lead of the mag lock.