3.3
Wiring the Operator Arm(s) for Pull to Open
1. Locate the wiring terminal board on the bottom of the
operator arm(s).
2. Wire the operator arms according to the diagram below.
NOTE: 1 indicates Master arm or Single operator connections, 2 indicates Slave arm if appli-
cable and is not used in single gate installations.
NOTE: Ground Terminal Screw indicates right from left as seen in picture on previous page, the
ground terminal screw however is not used on this model.
There is an Illustration to match the above chart on the previous page.
Push-To-Open wiring is found on the next page.
Wiring Connections for Operator Arm Power.
Position from
right in arm
Arm to Board
Wire Color
Terminal Pur-
pose
Board Connection
Terminal
M
Red
Lg. wire
Power
M1-1 (master)
M2-1 (slave - if dual)
M
Black
Lg. wire
Power
M1-2 (master)
M2-2 (slave - if dual)
COM
Red
Limit
Common
Limit 1 COM - Master
Limit 2 COM - Slave
FCC
Black
Limit
Closed
Position
CL1 / Limit 1 (master)
CL2 / Limit 2 (slave - if dual)
FCA
Yellow
Limit
Open
Position
OL1 / Limit 1 (master)
OL2 / Limit 2 (slave - if dual)
We have recently changed provided wire colors. If your wire colors do not match the
chart above and you need help determining terminal placement, call 1-800-640-GATE
for assistance.