3.5
Wiring the Operator Arm(s) for Push To Open
1. Locate the wiring terminal board on the bottom of the
operator arm(s).
2. Wire the operator arms according to the diagram below.
NOTE: 1 indicates Master arm or Single operator connections, 2 indicates Slave arm if
applicable and is not used in single gate installations.
Wiring Connections for Operator Arm Power.
Position
from
right in
arm
Arm to board
Wire Color
Terminal
Purpose
Board
Terminal
Block
Board Connection
Terminal
M
Red
Lg. Wire
Power
CN2
M1-2 (master)
M2-2 (slave - if dual)
M
Black
Lg. Wire
Power
CN2
M1-1 (master)
M2-1 (slave - if dual)
COM
Red
Limit
Common
CN3
Master - Limit 1 COM
Slave - Limit 2 COM
FCC
Black
Limit
Open
Position
CN3
OL1 - Limit 1 (master)
OL2 - Limit 2 (slave - if dual)
FCA
Yellow
Limit
Closed
Position
CN3
CL1 - Limit 1 (master)
CL2 - Limit 2 (slave - if dual)