Setting Closed Limit Switch - Push-to-Open
If the light does not go out before a physical limitation is reached, decrease the stroke length.
4.6
1. Insert limit buzzer. Place the bare end of the limit buzzer wire into the Limit1 CL1 terminal. Attach
the alligator clip from the other lead of the buzzer to the bare tip of the small yellow wire from the
operator arm.
2. Apply power to the circuit board as previous
seen in the instructions. The buzzer should be
sounding unless already on the open limit
switch.
3. Manually release the operator arm and slowly
move the gate from the closed position to the
open position. If the buzzer stops and starts
again while moving to this position make note
of this for the next step. Once the gate is in
your desired open position you are ready to
adjust the limit switch.
4. If the buzzer had turned off and back on while
moving the gate open: Turn the FCA screw
counter-clockwise until the buzzer stops.
If the buzzer did not turn off and back on while
moving the gate open: Turn the FCA screw
clockwise until the buzzer stops.
5. Your limit is now set for the open position and
you can remove the buzzer and put the yellow
wire directly into the CL1 terminal.