E145
20
732784 - Rev. A
ENGLISH
Display
Basic Function
Default
PA
PAUSE A TIME (visualised only with Automatic logics)
Is the pause time in a
TOTAL
opening (it is enabled only if a logic with pause
time has been selected).
Adjustable from
00
to
59
sec, in 1-second steps.
Next the value 59, the viewing changes to minutes and tenths of a second
(separated by a decimal point) and time is adjusted in 10-second steps up to
the maximum value of
9.5
minutes.
e.g.: if the display shows
2.5
, the time is 2 min and 50 sec.
30
Pb
PAUSE TIME B
(visualised only with Automatic logics):
Is the pause time in a
PARTIAL
opening (it is effective only if a logic with pause
time has been selected).
Adjustable from
00
to
59
sec, in 1-second steps.
Next the value 59, the viewing changes to minutes and tenths of a second
(separated by a decimal point) and time is adjusted in 10-second steps up to
the maximum value of
9.5
minutes.
Es: if the display shows
2.5
, the time is 2 min and 50 sec.
30
Mn
NR. OF MOTORS:
You can select the number of motors present in the system:
1
= 1 motor
2
= 2 motors
If the SETUP is performed with only one motor, and later two mo-
tors are used, the board will signal error
14
- configuration error,
which can be deleted by repeating the SETUP with two motors or
by returning to one motor.
If a SETUP is performed with two motors and later only one is used,
the board will not signal an error. Only the motor connected to input
M1 will move.
When programming from a PC/MAC, you can select different partial
openings.
2
(swing-
leaf)
1
(sliding)