E145
23
732784 - Rev. A
ENGLISH
Display
Basic Function
Default
M2
MOTOR 2 dead-man DRIVE mode (visualised only with the function
Mn
=
2
)
+/R1
OPENS (visualising
oP
) until the button is held down
-/R2
CLOSES (visualising
cL
) until the button is held down
--
M1
MOTOR 1 dead-man DRIVE mode
+/R1
OPENS (visualising
oP
) until the button is held down
-/R2
CLOSES (visualising
cL
) until the button is held down
--
tL
WORK TIME LEARNING (SETUP):
See the related paragraph.
--
St
AUTOMATED SYSTEM STATUS:
You can exit programming, choosing whether or not to save the configuration
you just performed.
1. set the choice:
Y
to SAVE and EXIT the programming
no
to EXIT the programming WITHOUT SAVING
2. press the button
F
to confirm; at the end the display returns to visualize
the
automated system status
:
Y
00
= CLOSED
01
= OPEN
02
= Stationary then “OPENS”
03
= Stationary then “CLOSES”
04
= In “PAUSE”
05
= during Opening
06
= during Closing
07
= FAIL SAFE in progress
08
= checking
BUS-2EASY
devices in progress
09
= Pre-flash then “OPENS”
10
= Pre-flash then “CLOSES”
11
=
Emergency open
12
=
Emergency close
HP
=
Hold position
WARNING If power is lost to the board prior to confirmation (step
2.), all changes made will be lost.
F
+
-/R2
You can EXIT programming at any time: press and hold F and
then also - to switch directly to
St
.