ENGLISH
FCA1, FCC1 and
GATECODER
1 correspond to LEAF 1;
FCA2, FCC2 and
GATECODER
2 correspond to LEAF 2.
4.4 J12 - PROGRAMMABLE OUTPUTS - ELECTRIC LOCKS
20
OUT2
24 V
"
(Open Collector) programmable using the function
o2
(advanced programming);
default:
indicator light
21
LOCK 1
Electric lock (12 V~ or 24 V
"
)
operated 2 sec before opening
of
leaf 1
When
BUS-2EASY
encoder is
disabled
, the electric
lock is operated before each opening (in whatever
position the stopped leaf is in).
When
BUS-2EASY
encoder is
enabled
, the electric
lock is operated only before opening the closed leaf.
22
LOCK 2
Electric lock (12 V~ or 24 V
"
)
-
operated 2 sec before opening
of
leaf 2
Other programming options are available by programming via a PC/MAC (see dedicated
instructions).
4.5 J12 -J6 - LIMIT SWITCH AND
GATECODER
The limit switch contacts FCC1, FCA1, FCC2, FCA2 are all NC contacts.
They are programmable using the functions
FA
and
FC
(basic programming) ; default:
disabled
.
If no limit switches are used, you DO NOT need to jumper the limit switch contacts
FCC1, FCA1, FCC2, FCA2.
You can however use a single
GATECODER
(only for single leaf); in this case, you do
not need to jumper the unused inputs to the earth.
Fig.
Limit switch and
GATECODER
connections (maximum configuration:
햴
).