![background image](http://html1.mh-extra.com/html/faac/e145/e145_manual_3097771040.webp)
E145
40
732784 - Rev. A
ENGLISH
8.2
ALARMS
When there is an ALARM the ERROR LED will begin to flash. By simultaneously pr
and - the display will show the corresponding alarm number.
The following table contains all the alarms that can be viewed on the display.
N°
ALARM
Solution/Description
2 0
Obstacle on MOTOR 1 (only with
encoder)
Remove any possible obstacle on leaf 1
2 1
Obstacle on MOTOR 2 (only with
encoder)
Remove any possible obstacle on leaf 2
2 5
LOCK 1 output short-circuit
Remove the cause of the short-circuit
2 6
LOCK 2 output short-circuit
Remove the cause of the short-circuit
2 7
Nr. of consecutive obstacles
exceeded during opening
Remove any possible obstacle.
Should the problem persist, repeat SETUP
2 8
Nr. of consecutive obstacles
exceeded during closing
Remove any possible obstacle.
Should the problem persist, repeat SETUP
3 0
XF
radio code memory full
Cancel the radio codes that are not being used using
the PC program or use an additional DEC/MINIDEC/
RP module
3 5
TIMER active and TIMER function
operating:
TIMER function is operating
4 0
Service request
Contact the installer for maintenance
5 0
The HOLD POSITION is operating
(active on PC/MAC )
HOLD POSITION function is operating
6 0
TIMER active and error in TIMER
data
Reload a correct TIMER configuration with the PC/MAC
programme
6 2
Loss of time and date on the board
(only if the TIMER is operating)
Reload the time and date with the PC/MAC programme
and replace the BAT1 - CR2032 buffer battery
6 3
JOLLY TIMER is activated
JOLLY TIMER is enabled by terminal board J3
6 4
TIMER DISABLED is operating TIMER is disabled by terminal board J3