5.2 ADVANCED PROGRAMMING FUNCTIONS
Display
Advanced Function
Default
bo
TIME OF MAXIMUM POWER AT STARTING:
You can set the starting time. During start the motors work at maximum power
for starting the movement.
Adjustable from
00
to
10
sec, in 1-second steps (ignoring the power level
selected with
F1
and
F2
).
01
cS
FINAL STROKE WHEN CLOSING (RAM STROKE) (NOT displayed if
function
FC
=
1
):
Lets you enable/disable the ram stroke on swing-leaves.
The ram stroke facilitates latching of the electric lock by activating the motors
at maximum power during final closing.
Y
= enabled (for 2 sec)
no
= disabled
In case of systems with an absolute encoder, to enable this function
a setup must be performed using the automatic leaf stop on the
mechanical contact point.
no
rS
REVERSE STROKE WHEN OPENING displayed if function
FA
=
1
):
Lets you enable/disable the reverse stroke on leaf doors.
The reverse stroke facilitates unlatching of the electric lock. When the auto-
matic system is closed, before starting to open, the motors give a brief push
to close.
Y
= enabled (for 2 sec)
no
= disabled
In case of systems with an absolute encoder, to enable this function
a setup must be performed using the automatic leaf stop on the
mechanical contact point.
no