![background image](http://html1.mh-extra.com/html/faac/e145/e145_manual_3097771008.webp)
E145
8
732784 - Rev. A
MAX
100 mA
{
C1
C2
J12
J3
J2
J1
9 10 11 12 13 14 15 16 17 18 19 20 21 22
PE N L
1 2 3 4 5 6 7 8
AC MAIN
PE
N
L
M1
1
2
3
LOCK
21
OUT2
20
OUT1
19
IN2
IN1
IN3 IN4 IN5
22
LAMP
7
8
24V
3W
230V~
MAX 60W
Mot1
Mot2
COM OP CL
OP-A
1
LOCK
2
OP-B STOP CL FSW OP
-
14
-
15
-
16
+
17
+
18
9 10 11 12 13
24V
M2
4
5
6
COM OP CL
MIN
90V~
MAX
260V~
50/60 Hz
12V ~
24V
12V ~
24V
*
*
J1
J2
J3
J12
{
MAX
500 mA
{
ENGLISH
4. ELECTRICAL CONNECTIONS
4.1 J1 - MAINS PRIMARY POWER SUPPLY
PE
Earthing Connection
For correct operation, you must con-
nect the switching power supply to the
system’s earthing conductor. Ensure
that upstream a suitable differential
magnetothermic switch has been in-
stalled.
N
Power Supply Connection from 90 V~ to 260
V~ Neutral
L
Power Supply Connection from 90 V~ to 260
V~ Line
Motor for SINGLE-LEAF or
FIRST LEAF when opening
(closes for the second)
OPEN A
Total gate opening
(contact N.O.)
OPEN B
Partial gate ope-
ning (contact N.O.)
STOP
Gate stop
(contact
N.C.)
*
Blue or grey
Photocells and safety de-
vices: for connections, see
the related paragraph.
4.2 J2 - MOTORS AND FLASHING LAMP
1
M1 - COM Common contact motor 1
M1 = first leaf when opening or single leaf
M2 = second leaf when opening - CAN-
NOT be used for single leaf
To verify correct wiring and direction
of motor rotation, (see
5.4 TIME LEAR-
NING - SETUP
)
2
M1 - OP
Opening phase motor 1
3
M1 - CL
Closing phase motor 1
4
M2 - COM Common contact motor 2
5
M2 - OP
Opening phase motor 2
6
M2 - CL
Closing phase motor 2
7
LAMP
Flashing lamp connection (MAX 60 W)
8