![background image](http://html1.mh-extra.com/html/faac/a1400-air/a1400-air_manual_3121388072.webp)
A1400 AIR
72
532129 04 - Rev.B
Tr
ansla
tion of the original instruc
tions
ENGLISH
(
*
)
value
EP
EP
:
programming with the SDK EVO offers a wider number of options compared to the board. The board does not display the values that are not available and indicates all of
them with EP (External Program). Programming with the board allows you to overwrite EP values by choosing an available value with the +/
-
buttons.
ADVANCED Function
CF1
CF2
CF3
CF4
CF5
In
In
Inputs status
The display segments correspond, each one has an input
and indicating whether it is active or not:
1
2
7
3
11
12
10
14
6
4
8
9
13
5
1
= S1 input
2
= S2 input
3
= manual release input
4
= always off
5
= Emergency 1 input
6
=always off
7
= always off
8
= I1 input
9
= I2 input
10
= FSW input
11
= I3 input
12
= I4 input
13
= Emergency 2 input
14
= always off
.
.
..
..
..
--
St
St
EXIT PROGRAMMING
It lets you exit programming, and decide whether to save or not the modifications made.
Y
Y
= save (only if there are NO configuration errors)
no
no
= do not save
Press F to confirm. After exit, the display shows automation status.
Y
Y
YY
YY
YY
--