AWS A5.17-97: F7A4-EM12K and A5.23-97: F8A2-EA1-A2

Publication C5.10.1   12/03

www.lincolnelectric.com

Lincolnweld

®

P223 flux is an industry

standard for spiral pipe welding on
up to X80 grade pipe, especially
where good impact properties are
required. It is also well-suited for
longitudinal seam welding on pipe,
producing a low bead profile with
very straight edges, while minimizing
undercuts. Its fast freezing slag
makes it ideal for even small diame-
ter pipe. In most cases, the slag is
self-peeling. For these same rea-
sons, P223 is an excellent choice for
many two-pass welding applications.
While designed for two-pass welding
applications, P223 is a neutral flux
which is also suitable for use in mul-
tiple pass welding with mild steel
and low alloy electrodes.

ADVANTAGE LINCOLN

• The weld deposits of neutral 

P223 flux are extremely resistant
to procedural variations.

• Fast solidification of weld metal

and slag for excellent bead
appearance.

• Low dust levels make handling at

the work station clean and easy.  

• Excellent weld profiles with straight

and consistent weld bead edges.

• Fast freezing slag makes P223

suitable for smaller diameter pipe.

• Slag is self-peeling on most appli-

cations.

• Designed to deliver Charpy 

V-Notch impact properties that
exceed most line pipe require-
ments.

• Low diffusible hydrogen levels.

• Manufactured under a quality 

system certified to ISO 9001.

TYPICAL APPLICATIONS

• Oil and gas line pipe fabrication

through X-80 grades.

• Single pass or multiple pass 

welding.

• Single arc or multiple arc (up to 

3 arc tandem welding).

• Straight seam or spiral seam 

welding.

PRODUCT INFORMATION

• Basicity Index: 1.60

• Particle Size: 

+12 Mesh  2% max.
-12/+100 Mesh  96% min.
-100 Mesh  2% max.

• Density: 1.3 g/cm

3

CONFORMANCES

For Mild Steel:

Lincolnweld

®

L- 61

AWS  A5.17-97: F7A4-EM12K
ASME  SFA-5.17

For Low Alloy Steel:

Lincolnweld

®

L-70

AWS  A5.23-97: F8A2-EA1-A2
ASME  SFA-5.23

RECOMMENDED ELECTRODES

Single Pass or Two-Pass Welds:

Lincolnweld

®

L-61, AWS EM12K

Lincolnweld

®

L-70, AWS EA1

(intended for applications requiring
robust Charpy impact properties).

Charpy V-Notch

Charpy V-Notch

Charpy V-Notch

Charpy V-Notch

Flux/Wire

ft•lbf (Joules)

ft•lbf (Joules)

ft•lbf (Joules)

ft•lbf (Joules)

Combination

@ 0ºF (-18ºC)

@ -20ºF (-29ºC)

@ -40ºF (-40ºC)

@ -60ºF (-51ºC)

Actual Test Results

75

76

87

45

As-welded

(101)

(103)

(117)

(61)

P223/L-61

Actual Test Results

113

101

99 

82

As-welded

(153)

(136)

(134)

(111)

P223/L-70

MECHANICAL PROPERTIES

(1)

Two-pass seam weld on 0.688" wall X-65 pipe
AC/AC two-wire tandem arc procedure

(1)

Mechanical property results obtained on single pass or two-pass welds will vary with base plate composition,

welding procedure, heat input, etc. These results are shown only to demonstrate the potential for the products
being used.

Tested on Pipe

Summary of Contents for P223 FLUX

Page 1: ...at exceed most line pipe require ments Low diffusible hydrogen levels Manufactured under a quality system certified to ISO 9001 TYPICAL APPLICATIONS Oil and gas line pipe fabrication through X 80 grades Single pass or multiple pass welding Single arc or multiple arc up to 3 arc tandem welding Straight seam or spiral seam welding PRODUCT INFORMATION Basicity Index 1 60 Particle Size 12 Mesh 2 max 1...

Page 2: ... and was employed only for the purpose of AWS classification The testing results and AWS classification shown should not be used to determine the suitability of this flux wire combination for service in limited pass applications Actual procedural tests should be conducted to verify the mechanical properties obtained on these applications DEPOSIT COMPOSITION As Required per AWS A5 17 97 A5 23 97 C ...

Page 3: ...in m min volts amps in min m min Side 1 Lead Arc P223 L 61 or L 70 90 2 3 35 920 41 1 04 5 32 4 0 mm AC 1 1 2 38 1 mm 5 8 15 88 mm Trail Arc P223 L 61 or L 70 50 1 3 36 640 41 1 04 5 32 4 0 mm AC 1 1 2 38 1 mm 5 8 15 88 mm Side 2 Lead Arc P223 L 61 or L 70 100 2 5 36 980 38 97 5 32 4 0 mm AC 1 1 2 38 1 mm 5 8 15 88 mm Trail Arc P223 L 61 or L 70 48 1 2 41 620 38 97 5 32 4 0 mm AC 1 1 2 38 1 mm 5 8...

Page 4: ... expand or alter any warranty with respect to the sale of our products Lincoln Electric is a responsive manufacturer but the selection and use of specific products sold by Lincoln Electric is solely within the control of and remains the sole responsibility of the customer Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication method...