![background image](http://html1.mh-extra.com/html/faac/a1400-air/a1400-air_manual_3121388082.webp)
A1400 AIR
82
532129 04 - Rev.B
Tr
ansla
tion of the original instruc
tions
ENGLISH
16. OPERATIONS ON THE BOARD
16.1 SET-UP
The SETUP consists of a series of movements.
WHEN IS SETUP NECESSARY
-
when the door automation is first put into operation
64
or
after replacing the board
-
when the display indicates error
15
15
-
following any travel variation
-
when leaf number (LN) is modified
-
after a reset to factory settings
SETUP CANNOT be performed in conditions of:
-
Emergency active
-
MANUAL mode
-
NIGHT-TIME mode
-
Power outage.
In this case the board remains in
L0
L0
status until the cause of the
problem has been removed.
HOW TO PERFORM SETUP FROM BOARD
-
To perform SETUP from board press button SW1 for 5 s.
0.0
RESET/SETUP
DL2
+
-
F
J
L0...L1...
L0...L1...L2
L2......
5 s
SW1
SETUP/RESET
SETUP is interrupted (status
L0
L0
) if one of the following occurs during
the procedure:
-
activation of an emergency command
-
setting NIGHT-TIME or MANUAL mode
-
activation of an error during motion.
-
Activation of the safeties does not prevent SETUP execution.
To perform the SETUP using SDK EVO refer to
102
.
16.2 RESET
Reset is an initialising procedure of board operation.
WHEN IS RESET NECESSARY
After automation lock due to:
-
a board error with a RESET request
HOW TO PERFORM A RESET FROM THE BOARD
-
Press the RESET button SW1 for 1 s and release it.
0.0
RESET/SETUP
DL2
+
-
F
J
SW1
SETUP/RESET
1 s
To perform a RESET using SDK EVO, refer to
69
.
16.3 RESTORING FACTORY STATUS
RESTORE brings all board parameters back to factory status.
!
The procedure is irreversible and involves:
- loss of data acquired from SETUP (need to perform SETUP again)
- loss of programming (resetting default values)
- relevant cycle counters are reset to zero
- loss of passwords (“0000” is reset)
WHEN IS RESTORE NECESSARY
When you wish to cancel all settings made on the board.
HOW TO PERFORM RESTORE
1. Disconnect mains power supply and disconnect the emergency
battery
2. restore power supply to the board
3.
within the first 4 s after switching on
(while the display shows the
FW version) press simultaneously for about 5 s the b
-
F
F
+ -
5 s
4. The display indicates
--
--
5. release the buttons
6. the display shows automation status.
!
After restoring factory status perform SETUP.
Summary of Contents for A1400 AIR
Page 1: ...A1400 AIR A1400 AIR DM EN16005 2012 E1SL fw 3 0 SDK EVO fw 30 LK EVO fw 1 2...
Page 122: ......
Page 124: ...A1400 AIR 124 53212904 Rev B...
Page 128: ...A1400 AIR 128 53212904 Rev B...
Page 129: ...A1400 AIR 129 53212904 Rev B...