18.1 ASSEMBLY AND TESTING
1. To separate the LK EVO use a flat screwdriver to prise apart the
points
100
.
2. Break off the cable knockout.
3. Mark the points on the wall
98
and fasten the support using
suitable screws.
F
BEFORE CONNECTING THE DEVICE, disconnect the power supply and the
emergency battery of the automation.
4. Connect the E1SL board
98
5. The connection must be made using a 4-pair twisted cable
U/UTP CAT.5 4x2xAWG24
with a 0.5 mm section
98
-
. The
maximum distance is 50 m.
6. Assemble the parts of the LK EVO by pressing slightly on the
points
98
.
* An optional connection can be made to terminals G and K on the LK EVO
with a key command to lock the function keys. With an NC contact, the
keypad is locked
98
-
.
TOTAL TWO-DIRECTION AUTOMATIC
DOOR OPEN
AUTOMATIC TOTAL
ONE-DIRECTIONAL
AUTOMATIC PARTIAL
TWO-DIRECTIONAL
NIGHT
MANUAL
18.2 SELECTION MENU
1. To access the operating mode selection menu, press the cor-
responding function button.
2. The following functions may be set with the selection buttons:
-
TOTAL TWO-DIRECTION AUTOMATIC
-
DOOR OPEN
-
AUTOMATIC TOTAL ONE-DIRECTION
-
AUTOMATIC PARTIAL TWO-DIRECTION AUTOMATIC
-
NIGHT
-
MANUAL
3. The LED switches on to identify the active function.
4. To switch to another function press the key corresponding to
the new function.