A1400 AIR
99
532129 04 - Rev.B
Tr
ansla
tion of the original instruc
tions
ENGLISH
MENU 1 LANGUAGE
Default: ITALIANO
■
INPUTS / OUTPUTS
OK
OK
INPUTS / OUTPUTS
2
PROGRAMMING
2 Inputs I1- I4
1. Select an input from the list:
-
I1
-
I2
-
I3
-
I4
2. Select function:
--
Disabled (0)
Disabled (0)
--
Open external (1)
Open external (1)
--
Open internal (4)
Open internal (4)
--
Open automatic (7)
Open automatic (7)
--
Open semi-automatic (8)
Open semi-automatic (8)
--
Pharmacy open (9)
Pharmacy open (9)
--
Key (10)
Key (10)
--
Partial Open (11)
Partial Open (11)
--
Closing safety (20)
Closing safety (20)
--
Opening safety (21)
Opening safety (21)
--
Emergency Open (30)
Emergency Open (30)
--
Emergency Open with memory (31)
Emergency Open with memory (31)
--
Emergency Stop (32)
Emergency Stop (32)
--
Emergency Stop with memory (33)
Emergency Stop with memory (33)
--
Emergency Closing (34)
Emergency Closing (34)
--
Emergency closing with memory (35)
Emergency closing with memory (35)
--
Modefun Open (40)
Modefun Open (40)
--
Modefun Exit only (41)
Modefun Exit only (41)
--
Modefun Entry only (42)
Modefun Entry only (42)
--
Modefun Night (43)
Modefun Night (43)
--
Modefun Manual (44)
Modefun Manual (44)
--
Modefun Partial (45)
Modefun Partial (45)
--
Modefun Interlock (46)
Modefun Interlock (46)
--
Timer (60)
Timer (60)
--
Reset (61)
Reset (61)
Default CF1 CF2 CF2 CF4 CF5
I1 1 1 1 1 --
I2 4 4 4 4 --
I3 10 10 10 10 --
I4 7 7 7 7 --
If the input has not been disabled, select the type of contact:
-
Normally open (NO)
-
Normally closed (NC)
Default CF1 CF2 CF2 CF4 CF5
Contact
Normally closed (NC)
--
3. If an input with CLOSURE SAFETY function has been selected, set
the TEST:
-
Enabled
-
Disabled
Default CF1 CF2 CF2 CF4 CF5
TEST
Disabled
--
4. Repeat the procedure for the other inputs.
3 Outputs O1 / O2
1. Select an input from the list:
-
O1
-
O2
2. Select function:
-
Disabled (0)
1
LANGUAGE
MENU 2 PROGRAMMING
The menu is only accessible if the INSTALLER password has been entered.
If a different password has been inserted, it is indicated: MENU RESERVED
FOR INSTALLERS.
The list is:
-
1 DOOR TYPE
-
2 INPUTS / OUTPUTS
-
3 MOTION
-
4 TIMING
-
5 ENERGY SAVING
-
6 BATTERY KIT
-
7 MOTOR BLOCK KIT
-
8 INSTALLATION
-
9 SUNDRIES
-
10 LOG
■
DOOR TYPE
■
OK
OK
DOOR TYPE
2
PROGRAMMING
1.
Select the type of door:
-
NO
-
A1000
-
A1400
-
RKE1400
-
SF1400
Default C F1 CF2 CF2 CF4 CF5
DOOR TYPE NO NO NO NO --
If SF1400 is selected, two other menus are displayed:
2.
NUMBER OF LEAVES select :
• 1
LEAF
• 2
LEAVES
3. PASSAGE
OPENING
with 1 LEAF selected:
• >=
75CM
• <=65CM
• >65CM
and <75cm
and <75cm
4. PASSAGE
OPENING
with 2 LEAVES selected:
• >=
150CM
• <=130CM
• >130CM
and <150cm
and <150cm
OK
OK
OK
OK
OK
OK
OK
ENGLISH
ITALIANO
FRANÇAIS
DEUTSCH
ESPANOL
NEDERLANDS
Summary of Contents for A1400 AIR
Page 1: ...A1400 AIR A1400 AIR DM EN16005 2012 E1SL fw 3 0 SDK EVO fw 30 LK EVO fw 1 2...
Page 122: ......
Page 124: ...A1400 AIR 124 53212904 Rev B...
Page 128: ...A1400 AIR 128 53212904 Rev B...
Page 129: ...A1400 AIR 129 53212904 Rev B...