A1400 AIR
100
532129 04 - Rev.B
Tr
ansla
tion of the original instruc
tions
ENGLISH
-
Gong (1)
-
Error (2)
-
Battery (3)
-
Emergency active (4)
-
Test for I1, I2, I3 and I4 (5)
-
Door not closed (6)
-
Door open (7)
-
Door in motion (8)
-
Light*(9)
-
Intrusion active (10)
-
Closing Safety (11)
-
Closing or Opening Safety (12)
(*) If this function is selected, set the time:
-
from 1s to 255s (Default 60s)
Default CF1 CF2 CF2 CF4 CF5
O1 6 6 6 6 --
O2 2 2 2 2 --
3. If the output has not been disabled, select the type of contact:
-
Normally open (NO)
-
Normally closed (NC)
Default CF1 CF2 CF2 CF4 CF5
Contact
Normally closed (NC)
--
4. Repeat the procedure for the other output.
3 Safety devices S1-S2
Select a SAFETY input:
-
S1
-
S2
5. Select function:
SEE INPUTS LIST I1-I4
Default CF1 CF2 CF2 CF4 CF5
S1
CLOSING SAFETY
--
S2
CLOSING SAFETY
--
6. If the input has not been disabled, set the TEST:
Default CF1 CF2 CF2 CF4 CF5
TEST
Enabled
--
-
Enabled
-
Disabled
7. If the input has not been disabled, select the logic:
-
Normally open (NO)
-
Normally closed (NC)
Default CF1 CF2 CF2 CF4 CF5
Contact
Normally closed (NC)
--
8. Repeat the procedure for the other inputs.
4 Emergencies E1 / E2
1. Select input E1 from the list:
-
E1
-
E2
2. Select function:
SEE INPUTS LIST I1-I4
Default CF1 CF2 CF2 CF4 CF5
E1 Disabled --
E2 Disabled --
3. If the input is enabled, select the type of contact:
-
Normally open (NO)
-
Normally closed (NC)
Default CF1 CF2 CF2 CF4 CF5
Contact
Normally open (NO)
--
5 XFA photocells
XFA photocell inputs are disabled by default.
1. Select:
-
Disabled
-
1 pair
-
2 pairs
Default CF1 CF2 CF2 CF4 CF5
XFA photocells Disabled
■
2 MOVEMENT
OK
OK
MOTION
2
PROGRAMMING
Opening
Select and modify the parameter from the list:
-
1 SPEED from 1 to 10
-
2 SLOWDOWN from 0 to 200 cm
SLOWDOWN SPEED from 1 to 3
-
3 FORCE from 1 to 10
-
4 FORCE TIME from 0.1 to 3.0s
-
5 ACCELERATION from 1 to 10
-
6 DECELERATION from 1 to 10
Default CF1 CF2 CF2 CF4 CF5
SPEED
10 8 8 5 ---
SLOWDOWN
1 1 1 1 ---
SLOWDOWN SPEED
1 1 1 1 ---
FORCE
8 8 8 8 ---
FORCE TIME
1.0 1.0
2.0
1.0 ---
ACCELERATION
8 8
5 8 ---
DECELERATION
6 6
6 4 ---
Closing
Select and modify the parameter from the list:
-
1 SPEED
from 1 to 10
-
2 SLOWDOWN
from 0 to 200cm
SLOWDOWN SPEED from 1 to 3
- 3 FORCE
from 1 to 10
-
4 FORCE TIME
from 0.1 to 3.0s
-
5 ACCELERATION
from 1 to 10
-
6 DECELERATION
from 1 to 10
-
7 REVERSE(*) 5
from 1 to 5
* the REVERSE parameter determines the reverse speed of the leaf during
closing with a 5-level setting from 1 (slow) to 5 (fast).