![background image](http://html1.mh-extra.com/html/faac/a1400-air/a1400-air_manual_3121388085.webp)
A1400 AIR
85
532129 04 - Rev.B
Tr
ansla
tion of the original instruc
tions
ENGLISH
17. INTERCOM (CANBUS)
PROGRAMMING
ONLY WITH SDKEVO
■
Description
The E1SL board is capable of communicating with other E1SL units
via an Intercom network connection. This enables the following
functions to be used (Programming/Intercom/Function menu):
-
INTERMODE: a master door from which to set the operating
mode for all the others that are connected to the network.
-
INTERLOCK: two single doors, where the opening of one is sub-
ject to the closing of the other and vice versa
!
Every network-connected E1SL should be programmed for the same
Intercom mode.
■
Connection
The units in the network are connected via 3 cascade connected-wires
between the J18 connectors of the E1SL boards
95
The sequence in which the units are wired is unimportant, but it is es-
sential that a CASCADE connection is used.
■
Addressing
A unique Node ID (Programming/Intercom/MasterSlave_no menu)
must be assigned to each E1SL in the network as indicated below.
!
Do not assign the same Node ID to more than one unit in the network.
■
Registration
After having wired up and assigned an address to each unit, reg-
istration must be carried out (Programming/Intercom/Intercom/
Node registration) only on the Master E1SL that has been assigned
Node ID=1.
J18
J18
G CH CL G
G CH CL G
J18
G CH CL G
95