![background image](http://html1.mh-extra.com/html/faac/a1400-air/a1400-air_manual_3121388026.webp)
A1400 AIR
26
532129 04 - Rev.B
15
16
17
14
1
1
1
2
2
3
2
8
3
2
8
3
4
6
Tr
ansla
tion of the original instruc
tions
ENGLISH
MOTOR RELEASE MONITOR
(OPTIONAL ACCESSORY)
Install the micro switch on the motor block
14
.
INTERNAL RELEASE
Double leaf applications.
For passage openings (Vp) of between 800 and 1000 mm, it is recom-
mended to install the release at the end opposite Motor_1.
For passage openings (Vp) of between 1000 and 3000 mm, it is recom-
mended to install the release close to Motor_1.
Release knobs are available for H100 or H140 covers. The method of as-
sembly and adjustment is the same for both versions.
The knob must be unscrewed and removed to open the automation casing
after mounting the internal release.
1. Turn the adjustment nut, with the relative locknut
15
-
.
2. Extract about 20 cm steel cable from the sheath. Insert the cable
into the adjustment nut and pass it into the release device
15
-
.
3. Tighten the screw
15
-
to lock the steel cable.
4. Move the black cable sheath against the adjustment screw and
screw the adjustment screw fully into the bracket.
5. Insert two plates into the profile
16
-
and install the release
knob on the side bracket.
6. Lock the knob: pull and turn it by 90°
15
. The knob must maintain
this position.
7. Run the cable with sheath into the suitable cable ducts up to the
motor block. Avoid bending the sheath too tightly.
8. Bring the cable with sheath close to part
17
and remove any
excess sheath.
9. Feed the cable into the guide
17
-
so that the sheath is in
contact with it. Insert the cable into the clamp
.
10. Pull the block
as far as it will go, compressing the springs.
Tighten the clamp screw
to lock the steel cable.
11. Cut the excess steel cable.
MOTOR BLOCK OPERATION TEST XB LOCK
The motor must be free to move: motor block not engaged in the
motor shaft coupling.
-
Use the adjustment nut to regulate the tension of the cable
15
-
.
-
Unlock the knob by turning it 90° and ensure the release is
working.
-
Pull the knob to make sure that the door opening micro switch
is activated
17
-
).
If installation of the external release is required, use suitable key buttons.
Insert the release cable in the suitable housing in the motor block.