44
ENGLISH
SETUP
The following parameters are checked and adjusted during
the Setup cycle:
• measurement of masses and friction, setting of speeds, plus
optimal acceleration and deceleration;
• acquisition of open and closed door positions;
• self-setting of the anti-crushing system at opening/closing
according to selected speeds.
During Setup, on the display flashes status 08 until the end of the
process if correctly executed.
Any faults are signalled by the display and by the diagnostics
via SD-Keeper.
Detection of serious faults (e.g. insufficient or excessive leaf travel,
too much friction, motor malfunctions) is signalled by the display
and by the diagnostics via SD-Keeper.
To activate a new Setup procedure, press and release the SW1
push-button on the board for more than 5 seconds and then
release it; Setup can also be started by a combination of push-
buttons on SD-Keeper (see relevant instructions).
The following are the situations in which, if required, the Setup
cycle is not executed, and the door stays in shut-down state,
generating an alarm signal (ALARM 15 on the display and on
SD-Keeper):
• door powered by battery;
• NIGHT operating function selected;
• MANUAL operating function selected;
• an emergency input is active;
• photocells
engaged;
• no power supplied to motor.
• external or internal release activated
When the cause has been eliminated, the Setup starts
automatically.
RESET
Whenever the automated system is powered, the door executes
a Reset cycle during which:
• the door’s travel limit positions are sought;
• any alarm signals are reset.
To activate a new Reset procedure, press the SW1 push-button
on the board for 1 second; Reset can also be started by a
combination of push-buttons on SD-Keeper (see relevant
instructions).
If a Reset is commanded while the door is in “Manual” mode, it
is executed when this operating function is exited.
In the “Night” operating function, Reset consists of a slow closing
movement, whereas it is normally a slow opening movement.
The reset procedure is necessary following the occurrence of
certain conditions causing the door to stop operating:
• after an obstacle is detected on 3 successive occasions
during closing/opening when the function NO STANDARD
OBSTACLE DETECTION (ALARM 8 or ALARM 9) has been
activated;
• after a “with memory”-configured emergency command
has been activated (see programming instructions), (ALARM
6 or ALARM 7);
• if, when using a motor lock kit, an opening malfunction is
detected on the kit.